文献速递甲状腺核医学核素与放射性配体治疗

术后131I SPECT/CT检测甲状腺残余组织比颈部超声更敏感

Postablative 131I SPECT/CT Is Much More Sensitive Than Cervical Ultrasonography for the Detection of Thyroid Remnants in Patients After Total Thyroidectomy for Differentiated Thyroid Cancer.
PubMed 文献 · Clin Nucl Med · 2020-01-01

本研究纳入154例分化型甲状腺癌全切术后患者,在131I消融后行颈部和SPECT/CT检查,比较颈部超声与SPECT/CT检测甲状腺残余组织(ThR)的敏感性。结果显示SPECT/CT在150例(97.4%)中发现341个碘摄取灶,而超声仅在118例(76.6%)中检出213个对应ThR,尤其对甲状软骨下缘以上区域的残余组织敏感性较低。

要点

  • SPECT/CT检出碘摄取灶的患者比例(97.4%)明显高于超声检出ThR的比例(76.6%)。
  • 超声对甲状软骨下缘以上外侧区及锥状叶/甲状舌管区残余组织的检出率仅30%–49%。
  • ThR体积与颈部碘摄取率强相关(r=0.79),与甲状腺球蛋白弱相关(r=0.24)。

核心结论

  • 对于分化型甲状腺癌全切术后患者,颈部超声检测甲状腺残余组织的敏感性低于131I治疗后SPECT/CT,尤其是位于甲状软骨下缘以上的残余组织。

研究设计与样本

  • 连续纳入154例(17–89岁,女123例、男31例)无已知癌残留或颈部淋巴结转移、术后14–20周行131I消融的分化型甲状腺癌患者。
  • 术前测定颈部碘摄取率(Tup)和甲状腺球蛋白,记录超声检测ThR的位置和体积;消融后第3–4天(给予1.7–4.6 GBq,即46–124.3 mCi 131I)行颈部SPECT/CT,将碘摄取灶按颈部区域分类并与超声结果比对。

主要发现

  • SPECT/CT在150例(97.4%)中共检出341个碘摄取灶,超声在118例(76.6%)中检出213个对应ThR。
  • 超声对甲状软骨下缘以上外侧区碘摄取灶的检出率为30%–46%,对锥状叶/甲状舌管区为49%(两者P<0.05)。
  • 超声对甲状软骨下缘以下外侧区检出率为74%–77%,对峡部为22%(两者P>0.05)。
  • ThR体积与Tup强相关(r=0.79),与甲状腺球蛋白弱相关(r=0.24)。

临床怎么用

  • 术后评估甲状腺残余组织时,应认识到颈部超声对特定区域(如甲状软骨下缘以上)残余组织敏感性有限,131I治疗后SPECT/CT可提供更敏感的残余组织定位信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Evaluation of utility of cervical ultrasound (US) for detection of thyroid remnants (ThR) in patients after thyroidectomy for differentiated thyroid cancer. METHODS: Included were 154 consecutive patients (17-89 years, 123 female and 31 male patients), without known cancer residues or cervical lymph nodes metastases, admitted for ThR ablation with I, 14 to 20 weeks after surgery. Neck uptake of I (Tup) and thyroglobulin were determined, and location and volume of ThR detected by cervical US were recorded. On days 3 to 4 after ablation (1.7-4.6GBq, 46-124.3 mCi I), neck SPECT/CT was performed, and I uptake foci were assigned to one of the regions as described below. The anterior neck was divided into 2 compartments: superior and inferior to lower margin of thyroid cartilage, and each compartment was subdivided into middle and lateral regions (in SPECT/CT, posterolateral and anterolateral regions were also marked out). I uptake sites and ThR detected by US, if congruent with SPECT/CT, were counted and analyzed. RESULTS: In total, 341 I uptake foci were found in 150 patients (97.4%) by SPECT/CT and 213 corresponding ThR in 118 patients (76.6%) by US. Ultrasound detected 30% to 46% of I uptake foci in superior lateral regions, 49% in pyramidal lobe/thyroglossal duct area (both P < 0.05), 74% to 77% in inferior lateral regions, and 22% in isthmus (both P > 0.05). Correlation between ThR volume and Tup was strong (r = 0.79), and that between ThR volume and thyroglobulin was weak (r = 0.24). CONCLUSIONS: Ultrasound is less sensitive than I posttherapy scans for ThR detection in patients after thyroidectomy, especially for remnants located above the lower margin of thyroid cartilage.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Bulzacka I, Makarewicz J. Postablative 131I SPECT/CT Is Much More Sensitive Than Cervical Ultrasonography for the Detection of Thyroid Remnants in Patients After Total Thyroidectomy for Differentiated Thyroid Cancer. Clin Nucl Med. 2020. PMID: 32969911. doi:10.1097/RLU.0000000000003295

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。