PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-09-29

本研究纳入121例临床常规[18F]Florbetaben PET图像,由三位专家在盲法条件下进行随机盲读研究。读片者先独立进行无定量辅助的视觉判读,间隔2周以上后再结合深度学习系统提供的定量结果判读。结果显示,深度学习辅助使基于3分BAPL评分的读片者间一致性Fleiss kappa从0.46提高到0.76,视觉判读信心评分从1.27±0.078提高到1.66±0.63。

要点

  • 深度学习定量辅助使BAPL视觉判读的读片者间一致性Fleiss kappa由0.46升至0.76。
  • 辅助读片时信心评分由1.27±0.078提高到1.66±0.63(3分制)。
  • 该端到端淀粉样蛋白负荷估计系统可改善临床常规淀粉样PET视觉判读。

核心结论

  • 基于深度学习的一步法淀粉样蛋白负荷估计系统可影响临床常规淀粉样PET读片的读片者间一致性与判读信心。

研究设计与样本

  • 随机盲读研究,收集121例临床常规[18F]Florbetaben PET图像。
  • 三位专家在盲于其他信息的条件下独立进行视觉判读,先无定量辅助读片,间隔2周以上后再结合深度学习系统定量结果读片。
  • 定性评估采用3分BAPL评分(1:无淀粉样负荷,2:轻度淀粉样负荷,3:显著淀粉样负荷)。
  • 每次读片以3分制评估信心评分(0:模糊,1:可能,2:确定)。

主要发现

  • 基于3分BAPL评分的读片者间一致性Fleiss kappa:无深度学习系统时为0.46,有深度学习系统时为0.76。
  • 视觉判读信心评分在有深度学习系统输出的读片 session 为1.66±0.63,仅视觉读片 session 为1.27±0.078。

关键数值与推荐

  • 定性判读采用3分BAPL评分:1为无淀粉样负荷,2为轻度淀粉样负荷,3为显著淀粉样负荷。
  • 信心评分采用3分制:0为模糊,1为可能,2为确定。

临床怎么用

  • 在临床常规淀粉样PET视觉判读中,可考虑结合深度学习端到端淀粉样负荷估计结果,以提高读片者间一致性和判读信心。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Amyloid PET which has been widely used for noninvasive assessment of cortical amyloid burden is visually interpreted in the clinical setting. As a fast and easy-to-use visual interpretation support system, we analyze whether the deep learning-based end-to-end estimation of amyloid burden improves inter-reader agreement as well as the confidence of the visual reading. METHODS: A total of 121 clinical routines [18F]Florbetaben PET images were collected for the randomized blind-reader study. The amyloid PET images were visually interpreted by three experts independently blind to other information. The readers qualitatively interpreted images without quantification at the first reading session. After more than 2-week interval, the readers additionally interpreted images with the quantification results provided by the deep learning system. The qualitative assessment was based on a 3-point BAPL score (1: no amyloid load, 2: minor amyloid load, and 3: significant amyloid load). The confidence score for each session was evaluated by a 3-point score (0: ambiguous, 1: probably, and 2: definite to decide). RESULTS: Inter-reader agreements for the visual reading based on a 3-point scale (BAPL score) calculated by Fleiss kappa coefficients were 0.46 and 0.76 for the visual reading without and with the deep learning system, respectively. For the two reading sessions, the confidence score of visual reading was improved at the visual reading session with the output (1.27 ± 0.078 for visual reading-only session vs. 1.66 ± 0.63 for a visual reading session with the deep learning system). CONCLUSION: Our results highlight the impact of deep learning-based one-step amyloid burden estimation system on inter-reader agreement and confidence of reading when applied to clinical routine amyloid PET reading.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。