文献速递心脏核医学

18F-flurpiridaz PET自动灌注定量系统的开发、诊断性能与观察者间一致性

Development, diagnostic performance, and interobserver agreement of a 18F-flurpiridaz PET automated perfusion quantitation system.
PubMed 文献 · J Nucl Cardiol · 2020-09-07

本研究基于18F-flurpiridaz III期试验的PET心肌灌注显像数据,开发了自动相对灌注定量方法,并在548例验证患者中与盲法视觉判读比较诊断性能。自动定量与视觉判读检测整体CAD的准确率相当(视觉71%和72%,自动72%和68%,分别对应CAD≥70%或≥50%狭窄)。在药物和运动负荷下,自动定量的观察者间一致性均显著优于视觉判读。

要点

  • 自动相对灌注定量检测整体CAD的准确率与视觉判读相当,达68%–72%。
  • 药物和运动负荷下,自动定量的观察者间一致性均显著高于视觉判读。
  • 该方法为18F-flurpiridaz PET MPI提供客观、可重复的定量评估。

核心结论

  • 18F-flurpiridaz PET自动相对灌注定量方法在正常和CAD受试者中提供定量、客观且高度可重复的评估。

研究设计与样本

  • 基于18F-flurpiridaz III期试验全部参与者的PET MPI研究,分为正常组N=40、推导组N=90和验证组N=548。

主要发现

  • 自动定量与视觉判读检测整体CAD的准确率相当:视觉为71%和72%,自动定量为72%和68%(分别对应CAD≥70%或≥50%狭窄)。
  • 分析单个冠状动脉区域时观察到相似结果。
  • 在药物和运动负荷下,自动定量的观察者间一致性均显著优于视觉判读。

关键数值与推荐

  • 以ROC曲线分析后低于正常均值的不同标准差作为显著CAD的截断值。
  • CAD显著性定义为≥70%或≥50%狭窄。

临床怎么用

  • 自动相对灌注定量可作为18F-flurpiridaz PET MPI的客观判读工具,在药物或运动负荷下提高观察者间一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Computerized methodologies standardize the myocardial perfusion imaging (MPI) interpretation process. METHODS: To develop an automated relative perfusion quantitation approach for 18F-flurpiridaz, PET MPI studies from all phase III trial participants of 18F-flurpiridaz were divided into 3 groups. Count distributions were obtained in N = 40 normal patients undergoing pharmacological or exercise stress. Then, N = 90 additional studies were selected in a derivation group. Following receiver operating characteristic curve analysis, various standard deviations below the mean normal were used as cutoffs for significant CAD, and interobserver variability determined. Finally, diagnostic performance was compared between blinded visual readers and blinded derivations of automated relative quantitation in the remaining N = 548 validation patients. RESULTS: Both approaches yielded comparable accuracies for the detection of global CAD, reaching 71% and 72% by visual reads, and 72% and 68% by automated relative quantitation, when using CAD ≥ 70% or ≥ 50% stenosis for significance, respectively. Similar results were observed when analyzing individual coronary territories. In both pharmacological and exercise stress, automated relative quantitation demonstrated significantly more interobserver agreement than visual reads. CONCLUSIONS: Our automated method of 18F-flurpiridaz relative perfusion analysis provides a quantitative, objective, and highly reproducible assessment of PET MPI in normal and CAD subjects undergoing either pharmacological or exercise stress.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Packard RRS, Cooke CD, Van Train KF, et al. Development, diagnostic performance, and interobserver agreement of a 18F-flurpiridaz PET automated perfusion quantitation system. J Nucl Cardiol. 2020. PMID: 32895856. doi:10.1007/s12350-020-02335-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。