全自动多参数PET直接Patlak重建的临床可行性与影响:103例动态全身18F-FDG PET/CT评估
该回顾性研究纳入109例拟行FDG PET/CT的患者,其中103例完成动态全身FDG PET/CT扫描并生成参数化MRFDG图像与标准静态SUV图像。视觉分析显示两者检出的病理病灶数量无差异,MRFDG图像假阳性比SUV图像少4个;定量分析中299/310个病灶的MRFDG TBR显著高于SUV TBR,且MRFDG CNR更优有助于低SUV TBR病灶的判读。结论认为动态全身FDG PET/CT临床可行,MRFDG图像对比度更优并可补充标准SUV图像,但未发现额外恶性病灶。
要点
- 103/109例完成动态全身FDG PET/CT,MRFDG图像视觉质量良好。
- MRFDG与SUV图像视觉检出病理病灶数无差异,MRFDG假阳性少4个。
- 299/310个病灶MRFDG TBR显著高于SUV TBR,低SUV TBR病灶判读更易。
核心结论
- 动态全身FDG PET/CT在临床环境中可行,生成的MRFDG图像视觉质量良好且病灶对比度优于标准SUV图像。
- MRFDG图像可补充标准SUV图像,提供更好的定量与图像判读,并减少假阳性发现,但未识别出额外恶性病灶。
- 该技术可能最适合特定患者群体或治疗反应评估。
研究设计与样本
- 回顾性研究,邀请109例涵盖广泛FDG PET/CT转诊指征的患者接受动态全身FDG PET/CT扫描。
- 生成参数化图像与标准静态SUV图像两套图像,进行视觉审阅,并对310个独立病灶用TBR和CNR指标做定量分析。
- 103/109例患者完成动态全身FDG PET/CT扫描。
主要发现
- MRFDG与SUV图像视觉识别的病理病灶数量无差异,MRFDG图像假阳性比SUV图像少4个。
- 310个病灶中299个的MRFDG TBR显著高于SUV TBR。
- MRFDG CNR更优,有助于低SUV TBR病灶的困难判读。
关键数值与推荐
- 定量分析指标为靶本比(TBR)与对比噪声比(CNR),共分析310个独立病灶。
- MRFDG TBR在299/310个病灶中显著高于SUV TBR。
- MRFDG图像假阳性较SUV图像少4个,视觉检出病理病灶数无差异。
临床怎么用
- 动态全身FDG PET/CT可用于临床生成MRFDG图像,视觉质量良好且病灶对比度优于标准SUV图像。
- MRFDG图像可补充标准SUV图像以改善定量与判读,尤其有助于低SUV TBR病灶的识别。
- 该技术可能适合特定患者群体或治疗反应评估,但不应期望其发现额外恶性病灶。
局限性
- 为回顾性研究设计。
- 109例中仅103例完成动态全身FDG PET/CT扫描。
- MRFDG图像虽减少假阳性,但未识别出额外恶性病灶。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Functional imaging by standard whole-body (WB) 18F-flurodeoxyglucose (FDG) positron emission tomography (PET) is an integrated part of disease diagnostics. Recently, a clinical dynamic whole-body (D-WB) FDG PET/CT scanning protocols has been developed allowing for quantitative imaging of tissue metabolic rate of FDG (MRFDG). It was the purpose of this retrospective study to evaluate whether MRFDG imaging is feasible in a clinical setting and whether it improves lesion detectability. METHODS: One hundred nine patients representing a broad range of referral indications for FDG PET/CT were invited to undergo a D-WB FDG PET/CT scan. Two sets of images were produced: parametric images and standard static SUV images. Both sets of images were reviewed visually, and 310 individual lesions were quantitatively analysed using the target-to-background (TBR) and contrast-to-noise (CNR) metrics. RESULTS: One hundred three out of 109 patients completed the D-WB FDG PET/CT scan. There was no difference in the number of pathological lesions identified visually on the MRFDG and the SUV images, whereas MRFDG images yielded 4 fewer false positives than the SUV images. Quantitatively, MRFDG TBR was significantly higher than SUV TBR in 299/310 lesions, and better MRFDG CNR was found to facilitate the challenging reading of lesions with low SUV TBR. CONCLUSION: D-WB FDG PET/CT is feasible in a clinical setting and produces MRFDG images of good visual quality and superior lesion contrast. In addition, MRFDG images complement the standard SUV images providing better quantification and enhanced image reading. However, although MRFDG also reduced the number of false-positive findings, no additional malignant lesions were identified. The technique therefore appears to be best suited for select patient groups or possibly treatment response evaluation.
引用
- Dias AH, Pedersen MF, Danielsen H, et al. Clinical feasibility and impact of fully automated multiparametric PET imaging using direct Patlak reconstruction: evaluation of 103 dynamic whole-body 18F-FDG PET/CT scans. Eur J Nucl Med Mol Imaging. 2020. PMID: 32894338. doi:10.1007/s00259-020-05007-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。