PET/CT联合CT结肠成像在光学结肠镜不完整梗阻性结直肠癌术前诊断中的前瞻性研究
该前瞻性研究纳入47例因梗阻性肿块导致光学结肠镜未完成的疑似结直肠癌患者,评估全身PET/CT联合CT结肠成像(PET/CTC)的术前诊断价值。所有肿瘤均显示FDG摄取,PET/CTC对≥10 mm息肉有潜在排除价值,但对小息肉识别有限;PET/CTC对肝转移诊断的敏感性和特异性均为100%。
要点
- PET/CTC对所有结直肠癌原发灶均显示FDG摄取,可诊断同时性肿瘤。
- PET/CTC未能识别小于10 mm的息肉,但≥10 mm息肉均显示FDG摄取。
- PET/CTC对肝转移的敏感性和特异性均为100%,优于CTC。
核心结论
- PET/CTC是结直肠癌分期和诊断同时性肿瘤的可靠技术。
- PET/CTC不能识别小息肉,但具有排除≥10 mm高恶性风险息肉的潜在用途。
研究设计与样本
- 前瞻性纳入47例因梗阻性肿块导致光学结肠镜未完成的疑似结直肠癌患者,其中女性18例、男性29例,平均年龄71±14岁。
- PET/CTC操作时插入小口径Foley导管并注入CO2扩张结肠,所有发现均经组织学证实。
主要发现
- 结直肠癌位于乙状结肠(n=21)、直肠(n=7)、直乙交界(n=5)、升结肠(n=7)、降结肠(n=5)和横结肠(n=2)。
- 所有肿瘤均显示FDG摄取,平均SUVmax为20.02±9.9,包括1例同时性肿瘤(SUVmax为10.46)。
- 47个息肉经组织学证实为小于10 mm(n=35)和10 mm或更大(n=12),所有12个≥10 mm息肉均显示FDG摄取(SUVmax范围3.08-19.5),但仅1个小于10 mm的息肉被PET识别。
- 术后病理诊断淋巴结转移17/47例,CTC诊断的敏感性和特异性分别为71%和97%,PET/CTC分别为59%和100%。
- 9例患者确认肝转移,其中4/9合并肺转移(n=2)或种植转移(n=2),CTC诊断肝转移的敏感性和特异性分别为89%和100%,PET/CTC均为100%。
关键数值与推荐
- 息肉直径≥10 mm被视为高恶性风险。
- PET/CTC对≥10 mm息肉均显示FDG摄取,SUVmax范围3.08-19.5。
- PET/CTC诊断病理淋巴结的敏感性和特异性分别为59%和100%。
- PET/CTC诊断肝转移的敏感性和特异性均为100%。
临床怎么用
- 对于光学结肠镜因梗阻性肿块未完成的疑似结直肠癌患者,可考虑PET/CTC进行术前分期和同时性肿瘤诊断。
- PET/CTC可用于排除≥10 mm的高恶性风险息肉,但不能替代对小于10 mm息肉的识别。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: The aim of this study was to evaluate if integrating whole-body PET/CT with CT colonography (PET/CTC) improves the preoperative diagnosis of obstructive colorectal cancer (CRC). METHODS: We prospectively included 47 consecutive patients (18 women and 29 men; mean age, 71 ± 14 years) suspected of having CRC by optical colonoscopy, which was not completed due to obstructive masses. To perform PET/CTC, a small caliber Foley catheter was inserted to distend the colon with CO2 insufflations. Polyps measuring 10 mm or larger were considered as high risk of malignancy. All findings were histologically confirmed. RESULTS: Colorectal cancer was localized in the sigmoid (n = 21), rectum (n = 7), rectosigmoid junction (n = 5), ascending (n = 7), descending (n = 5), and transverse (n = 2) colon. All tumors showed FDG uptake (mean ± SD SUVmax, 20.02 ± 9.9) including one synchronic tumor (SUVmax, 10.46). Forty-seven polyps were histologically confirmed as smaller than 10 mm (n = 35) and 10 mm or larger (n = 12). All 12 polyps 10 mm or larger showed FDG uptake (SUVmax range, 3.08-19.5), but only one smaller than 10 mm could be identified by PET. Pathological lymph nodes were diagnosed in 17/47 cases after surgical removal with a sensitivity and specificity for CTC and PET/CTC of 71% and 97% and 59% and 100%, respectively. Liver metastases were confirmed in 9 patients and in 4/9 along with lung metastases (n = 2) or implants (n = 2), showing a sensitivity and specificity for CTC of 89% and 100% and both 100% for PET/CTC. CONCLUSIONS: PET/CTC is a reliable technique for staging CRC and diagnosing synchronous tumors. In this series, PET/CTC was not able to identify small polyps but showed potential use for ruling out 10 mm or larger polyps at high risk of malignancy.