文献速递肿瘤 PET/CT

18F-FDG PET与DCE动力学模型在原发性非小细胞肺癌中的体素级相关性分析

18F-FDG PET and DCE kinetic modeling and their correlations in primary NSCLC: first voxel-wise correlative analysis of human simultaneous [18F]FDG PET-MRI data.
PubMed 文献 · EJNMMI Res · 2020-07-30

该研究对14例未经治疗的非小细胞肺癌患者进行动态同步18F-FDG PET-MRI扫描,采用体素级分析探究PET与DCE动力学参数的相关性。结果显示PET与DCE参数间相关性多为低至中等(|rs|<0.7),提示两者可能提供互补信息,动态「一站式」检查在临床中技术可行。

要点

  • 动态同步18F-FDG PET-MRI在非小细胞肺癌临床中技术可行。
  • PET与DCE动力学参数在体素级上多呈低至中等相关(|rs|<0.7)。
  • 半数肿瘤表现为低代谢且低灌注/血管化 profile,提示缺氧和侵袭性。

核心结论

  • 动态「一站式」PET-MRI流程在非小细胞肺癌临床实践中技术可行。
  • PET与DCE动力学参数在非小细胞肺癌中相关性不高且肿瘤间变异大,提示可能提供互补信息。

研究设计与样本

  • 前瞻性纳入14例活检证实的未经治疗非小细胞肺癌患者,行1小时动态18F-FDG胸部PET-MRI扫描(含DCE)。
  • PET和DCE数据归一化至T1加权MR形态空间,半自动勾画肿瘤,分别用Sokoloff和Extended Tofts模型拟合得到体素级参数图。

主要发现

  • 约90%的PET体素拟合误差低于20%(中位rRMSE=10.3,IQR=8.1;14.3)。
  • 73.3%的DCE体素拟合误差低于45%(中位rRMSE=31.8%,IQR=22.4;46.6)。
  • PET-PET和DCE-DCE体素级相关性主要高(|rs|>0.7),而PET-DCE相关性主要低至中等(|rs|<0.7)。
  • 半数肿瘤显示低代谢伴低灌注/血管化特征,为缺氧和肿瘤侵袭性的标志。

临床怎么用

  • 动态同步18F-FDG PET-MRI可作为非小细胞肺癌患者个体化生物学行为表征的潜在工具。
  • PET与DCE动力学参数互补,可能联合用于评估肿瘤缺氧和侵袭性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To decipher the correlations between PET and DCE kinetic parameters in non-small-cell lung cancer (NSCLC), by using voxel-wise analysis of dynamic simultaneous [18F]FDG PET-MRI. MATERIAL AND METHODS: Fourteen treatment-naïve patients with biopsy-proven NSCLC prospectively underwent a 1-h dynamic [18F]FDG thoracic PET-MRI scan including DCE. The PET and DCE data were normalized to their corresponding T1-weighted MR morphological space, and tumors were masked semi-automatically. Voxel-wise parametric maps of PET and DCE kinetic parameters were computed by fitting the dynamic PET and DCE tumor data to the Sokoloff and Extended Tofts models respectively, by using in-house developed procedures. Curve-fitting errors were assessed by computing the relative root mean square error (rRMSE) of the estimated PET and DCE signals at the voxel level. For each tumor, Spearman correlation coefficients (rs) between all the pairs of PET and DCE kinetic parameters were estimated on a voxel-wise basis, along with their respective bootstrapped 95% confidence intervals (n = 1000 iterations). RESULTS: Curve-fitting metrics provided fit errors under 20% for almost 90% of the PET voxels (median rRMSE = 10.3, interquartile ranges IQR = 8.1; 14.3), whereas 73.3% of the DCE voxels showed fit errors under 45% (median rRMSE = 31.8%, IQR = 22.4; 46.6). The PET-PET, DCE-DCE, and PET-DCE voxel-wise correlations varied according to individual tumor behaviors. Beyond this wide variability, the PET-PET and DCE-DCE correlations were mainly high (absolute rs values > 0.7), whereas the PET-DCE correlations were mainly low to moderate (absolute rs values < 0.7). Half the tumors showed a hypometabolism with low perfused/vascularized profile, a hallmark of hypoxia, and tumor aggressiveness. CONCLUSION: A dynamic "one-stop shop" procedure applied to NSCLC is technically feasible in clinical practice. PET and DCE kinetic parameters assessed simultaneously are not highly correlated in NSCLC, and these correlations showed a wide variability among tumors and patients. These results tend to suggest that PET and DCE kinetic parameters might provide complementary information. In the future, this might make PET-MRI a unique tool to characterize the individual tumor biological behavior in NSCLC.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Besson FL, Fernandez B, Faure S, et al. 18F-FDG PET and DCE kinetic modeling and their correlations in primary NSCLC: first voxel-wise correlative analysis of human simultaneous [18F]FDG PET-MRI data. EJNMMI Res. 2020. PMID: 32734484. doi:10.1186/s13550-020-00671-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。