文献速递甲状腺核医学肿瘤 PET/CT

甲状腺球蛋白倍增时间优于甲状腺球蛋白水平用于筛选非碘摄取型分化型甲状腺癌患者行[18F]FDG PET/CT定位

Thyroglobulin doubling time offers a better threshold than thyroglobulin level for selecting optimal candidates to undergo localizing [18F]FDG PET/CT in non-iodine avid differentiated thyroid carcinoma.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-08-13

ROC分析显示TgDT最佳截断值为2.5年(敏感度93%、特异度87%、AUC=0.911),优于Tg水平截断值19 ng/mL(敏感度78%、特异度85%、AUC=0.844),且TgDT≤2.5年预测PET/CT结果显著优于Tg水平(p=0.023)。

要点

  • TgDT≤2.5年预测[18F]FDG PET/CT阳性敏感度93%、特异度87%。
  • TgDT预测PET/CT结果显著优于绝对Tg水平(p=0.023)。
  • TgDT可作为筛选非碘摄取型DTC患者行FDG PET/CT的优选指标。

核心结论

  • 当TgDT≤2.5年时,[18F]FDG PET/CT的诊断性能较使用绝对Tg水平显著提高。

主要发现

  • [18F]FDG PET/CT的敏感度、特异度、阳性预测值、阴性预测值和准确率分别为92%、94%、97%、87%和93%。
  • PET/CT阳性患者的Tg和TgDT均高于PET/CT阴性患者。

关键数值与推荐

  • ROC曲线分析显示Tg最佳截断值为19 ng/mL(敏感度78%,特异度85%,AUC=0.844)。
  • TgDT最佳截断值为2.5年(敏感度93%,特异度87%,AUC=0.911)。
  • TgDT截断值2.5年预测PET/CT结果显著优于Tg水平(p=0.023)。

临床怎么用

  • 在非碘摄取型DTC患者中,可计算TgDT并以≤2.5年作为筛选[18F]FDG PET/CT的参考阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To investigate the potential role of serum thyroglobulin doubling time (TgDT) in predicting 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) PET/CT results in patients affected by differentiated thyroid carcinoma (DTC) who demonstrated a combination of positive Tg but a negative [131I] whole-body scan ([131I]-WBS). MATERIALS AND METHODS: Inclusion criteria were (1) prior [131I] treatment for DTC, (2) negative subsequent [131I]-WBS, (3) no interfering anti-Tg antibodies, (4) three consecutive Tg measurements under the thyroid hormone replacement therapy to calculate TgDT before 2-[18F]FDG PET/CT, and (5) at least 6 months of clinical and/or imaging follow-up to ascertain the diagnosis. Receiver operating characteristic (ROC) curve and the area under the curve (AUC) were used to identify the optimal cutoff point for the last stimulated Tg and TgDT prior to [18F]FDG PET/CT. RESULTS: One hundred and thirteen patients were included. Seventy-four (65%) patients had positive [18F]FDG PET/CT for DTC recurrence, while the remaining 39 (35%) negative. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of [18F]FDG PET/CT were 92%, 94%, 97%, 87%, and 93%. Patients with positive [18F]FDG PET/CT had higher Tg and TgDT than those with negative PET/CT. ROC curve analysis revealed an optimal Tg cutoff of 19 ng/mL (sensitivity 78%, specificity 85%, AUC = 0.844) and TgDT of 2.5 years (sensitivity 93%, specificity 87%, AUC = 0.911). TgDT threshold of 2.5 years predicted significantly (p = 0.023) better than Tg level PET/CT results. CONCLUSIONS: The diagnostic performance of [18F]FDG PET/CT could be significantly improved when TgDT is less than or equal to 2.5 years, as compared with using the absolute Tg level.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Albano D, Tulchinsky M, Dondi F, et al. Thyroglobulin doubling time offers a better threshold than thyroglobulin level for selecting optimal candidates to undergo localizing [18F]FDG PET/CT in non-iodine avid differentiated thyroid carcinoma. Eur J Nucl Med Mol Imaging. 2020. PMID: 32794104. doi:10.1007/s00259-020-04992-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。