文献速递肿瘤 PET/CT

NPM1过表达与肺腺癌18F-FDG PET/CT代谢参数相关并提高诊断准确性

Nucleophosmin 1 overexpression correlates with 18F-FDG PET/CT metabolic parameters and improves diagnostic accuracy in patients with lung adenocarcinoma.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-08-27

SUVmax、SUVmean和TLG与NPM1表达相关(p < 0.001),SUVmax是NPM1表达的主要预测因子(p < 0.01),SUVmax cutoff值3.93预测NPM1过表达的敏感性为90.9%、特异性为84.6%。

要点

  • NPM1在肺腺癌中表达高于癌旁正常肺组织,诊断准确性优于TTF1。
  • SUVmax、SUVmean和TLG与NPM1表达显著相关(p < 0.001)。
  • SUVmax cutoff值3.93预测NPM1过表达:敏感性90.9%、特异性84.6%。

核心结论

  • NPM1过表达与18F-FDG PET/CT代谢参数相关,并提高肺腺癌诊断准确性。
  • 18F-FDG PET/CT的SUVmax或可无创评估肺腺癌NPM1表达,辅助靶向治疗决策。

研究设计与样本

  • 从PET影像计算SUVmax、SUVmean、MTV和TLG,并用TCGA数据库及肿瘤组织与癌旁正常肺组织免疫组化评估NPM1和TTF1表达。

主要发现

  • 肺腺癌组织NPM1表达高于癌旁正常肺上皮组织。
  • NPM1诊断肺腺癌的敏感性和特异性均高于TTF1(p < 0.001)。
  • SUVmax、SUVmean和TLG与NPM1表达相关(p < 0.001)。
  • MTV与TTF1表达呈负相关(p < 0.01)。
  • SUVmax是肺腺癌NPM1表达的主要预测因子(p < 0.01)。

关键数值与推荐

  • SUVmax cutoff值3.93预测NPM1过表达的敏感性为90.9%、特异性为84.6%。

临床怎么用

  • 对肺腺癌患者,可参考术前18F-FDG PET/CT的SUVmax评估NPM1过表达可能性,为靶向治疗提供无创依据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study investigated the correlation of nucleophosmin 1 (NPM1) expression with 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computerised tomography scan (PET/CT)-related parameters and compared the diagnostic value of NPM1 with that of the positive biomarker TTF1 in lung adenocarcinoma patients. METHODS: Forty-six lung adenocarcinoma patients who underwent 18F-FDG PET/CT before pulmonary surgery were retrospectively analysed. Metabolic parameters including SUVmax, SUVmean, metabolic tumour volume (MTV) and total lesion glycolysis (TLG) were calculated from 18F-FDG PET imaging data. The expression levels of NPM1 and TTF1 were assessed using The Cancer Genome Atlas (TCGA) database and immunohistochemistry of tumour tissues and adjacent normal lung tissues. We examined the association between the frequency of NPM1 and TTF1 expression and the metabolic parameters. RESULTS: Lung adenocarcinoma samples expressed higher levels of NPM1 than adjacent normal lung epithelial tissues. NPM1 showed higher specificity and sensitivity for lung adenocarcinoma compared with TTF1 (p < 0.001). SUVmax, SUVmean and TLG correlated with NPM1 expression (p < 0.001). MTV was inversely correlated with TTF1 (p < 0.01). SUVmax was the primary predictor of NPM1 expression by lung adenocarcinoma (p < 0.01). A cutoff value for the SUVmax of 3.93 allowed 90.9% sensitivity and 84.6% specificity for predicting NPM1 overexpression in lung adenocarcinoma. CONCLUSION: NPM1 overexpression correlated with 18F-FDG PET/CT metabolic parameters and improved diagnostic accuracy in lung adenocarcinoma. SUVmax on 18F-FDG PET/CT may estimate NPM1 expression for targeted therapy of lung adenocarcinoma.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Zhou LM, Yuan LL, Gao Y, et al. Nucleophosmin 1 overexpression correlates with 18F-FDG PET/CT metabolic parameters and improves diagnostic accuracy in patients with lung adenocarcinoma. Eur J Nucl Med Mol Imaging. 2020. PMID: 32856112. doi:10.1007/s00259-020-05005-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。