颈内动脉狭窄程度、MR血管成像壁面剪切应力与18F-FDG摄取的关系初探
本初步研究纳入20例颈动脉粥样硬化患者的40条颈动脉,用MRA计算流体力学分析测量最大壁面剪切应力(WSSmax),用PET/CT测量颈内动脉18F-FDG最大靶本底比(TBRmax),并按NASCET法计算狭窄程度。结果显示WSSmax与狭窄程度、WSSmax与TBRmax、TBRmax与狭窄程度均显著相关。
核心结论
- 在颈动脉狭窄患者中,颈内动脉狭窄程度、WSSmax与TBRmax之间可能存在显著相关性。
研究设计与样本
- 初步研究,纳入20例颈动脉粥样硬化患者的40条颈动脉,行MRA与18F-FDG PET/CT检查,并评估动脉粥样硬化危险因素。
- 狭窄程度按NASCET法计算,经计算流体力学分析测量WSSmax,18F-FDG摄取以TBRmax量化。
主要发现
- 动脉粥样硬化危险因素未影响影像学表现。
关键数值与推荐
- 狭窄程度采用NASCET法计算。
- 18F-FDG摄取量化指标为TBRmax,WSS经计算流体力学分析测得WSSmax。
临床怎么用
- 提示可将MRA计算流体力学所得WSS与PET/CT的18F-FDG摄取联合用于颈动脉粥样硬化斑块评估,但仅为初步结果,尚需进一步验证。
局限性
- 为初步研究,样本量小(20例患者、40条颈动脉),结论需更大样本研究证实。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This preliminary study was undertaken to evaluate relationship among the degree of internal carotid artery (ICA) stenosis, wall shear stress (WSS) by computational fluid dynamics (CFD) on magnetic resonance angiography (MRA) and 18F-FDG uptake of ICA on PET/CT. METHODS: A total of 40 carotid arteries in 20 patients with carotid atherosclerotic disease were examined with MRA and 18F-FDG PET/CT. Atherosclerotic risk factors were assessed in all patients. Degree of ICA stenosis was calculated according to NASCET method. CFD analysis was performed and maximum WSS (WSSmax) was measured. 18F-FDG uptake in ICA was quantified using maximum target-to-blood pool ratio (TBRmax). RESULTS: Atherosclerotic risk factors did not affect imaging findings. There were significant correlations between WSSmax and degree of ICA stenosis (ρ = .81, P < .001), WSSmax and TBRmax (ρ = .64, P < .001), and TBRmax and degree of ICA stenosis (ρ = .50, P = .001). CONCLUSIONS: These preliminary results indicate that there may be significant correlations among the degree of ICA stenosis, WSSmax and TBRmax in patients with carotid artery stenosis.
引用
- Takami Y, Norikane T, Yamamoto Y, et al. A preliminary study of relationship among the degree of internal carotid artery stenosis, wall shear stress on MR angiography and 18F-FDG uptake on PET/CT. J Nucl Cardiol. 2020. PMID: 32743752. doi:10.1007/s12350-020-02300-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。