文献速递肿瘤 PET/CT放射性药物与辐射防护

食管癌淋巴结18F-FDG摄取与病理诊断的逐一比较

One-by-One Comparison of Lymph Nodes Between 18F-FDG Uptake and Pathological Diagnosis in Esophageal Cancer.
PubMed 文献 · Clin Nucl Med · 2020-01-01

该前瞻性研究在20例食管癌患者中,对1073枚淋巴结(含38枚转移)逐一测量离体淋巴结FDG放射性,并与病理诊断及术前FDG PET分站视觉分析比较。结果显示,基于ROC曲线截断值的逐枚淋巴结分析敏感度94.7%、特异度78.7%,准确度高于淋巴结重量或最短径;分站分析敏感度28.6%、特异度96.7%。

要点

  • 逐枚淋巴结FDG放射性测量诊断转移的敏感度94.7%、特异度78.7%。
  • 分站FDG PET视觉分析敏感度28.6%、特异度96.7%。
  • 逐枚淋巴结FDG摄取准确度高于淋巴结重量或最短径。

核心结论

  • 每枚淋巴结的FDG摄取是食管癌导航手术的潜在有用标志物,且准确度高于淋巴结重量或直径。

研究设计与样本

  • 前瞻性研究纳入20例食管癌患者,共分析1073枚淋巴结,其中38枚为转移淋巴结。
  • 术前同日行FDG PET并按淋巴结站视觉分析异常摄取,术后用井型计数器测量每枚离体淋巴结FDG放射性,与病理诊断逐一比较。

主要发现

  • 基于淋巴结站的分析敏感度28.6%、特异度96.7%。
  • 基于逐枚淋巴结的分析(截断值来自ROC曲线)敏感度94.7%、特异度78.7%。
  • 逐枚淋巴结FDG摄取诊断准确度高于使用淋巴结重量或最短径。

关键数值与推荐

  • 逐枚淋巴结分析的截断值由ROC曲线获得,原文未报告具体数值。
  • 分站分析敏感度28.6%、特异度96.7%;逐枚分析敏感度94.7%、特异度78.7%。

临床怎么用

  • 术中可借助γ探头或放射性探测器测量每枚淋巴结FDG放射性,辅助导航手术决策。
  • 逐枚淋巴结FDG测量较淋巴结重量或最短径更准确,但需注意ROC截断值需本地化验证。

局限性

  • 样本量较小(20例患者、38枚转移淋巴结),结论需更大样本验证。
  • 逐枚淋巴结分析的截断值来自ROC曲线,原文未报告具体数值及验证方式。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Esophagectomy with extended lymph node (LN) dissection is a standard treatment for resectable esophageal cancer to prevent recurrence, but severe, potentially life-threatening postoperative complications are still important issues. Accurate diagnosis of LN metastases would enable the decision to dissect or leave the LNs in regions with high risk of complications. Advancements in intraoperative gamma probe and radioactivity detectors have made intraoperative navigation surgery possible using a radiotracer as a marker. F-FDG is one such candidate markers, and the diagnostic power of FDG through counting the radioactivity close to each LN should be elucidated. MATERIALS AND METHODS: In 20 patients, 1073 LNs including 38 metastatic LNs were prospectively investigated. Preoperative FDG PET was performed on the same day before esophagectomy and visually surveyed in each LN station to identify abnormal uptake. The FDG radioactivity of each individual dissected LN was measured by a well-type counter, and the pathological diagnosis was compared with LN radioactivity on a one-by-one basis and with the preoperative FDG PET findings for each LN station. RESULTS: Lymph node station-based analysis showed a sensitivity and specificity of 28.6% and 96.7%, respectively. One-by-one LN-based analysis using a cutoff value obtained from the receiver operating characteristic curve showed a sensitivity and specificity of 94.7% and 78.7%, respectively, demonstrating higher accuracy compared with the use of LN weight or the shortest diameter. CONCLUSIONS: The FDG uptake by each LN is a potentially useful marker for navigation surgery in esophageal cancer and has higher accuracy than LN weight or diameter.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Yoshimura S, Takahashi M, Aikou S, et al. One-by-One Comparison of Lymph Nodes Between 18F-FDG Uptake and Pathological Diagnosis in Esophageal Cancer. Clin Nucl Med. 2020. PMID: 32796247. doi:10.1097/RLU.0000000000003224

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。