脐部饰品致梅克尔憩室显像假阳性一例
SPECT/CT将摄取灶定位于脐周,考虑为脐部饰品所致局部炎症引起的假阳性。
要点
- 梅克尔憩室显像前应询问并检查脐部饰品等可能致假阳性的因素。
- 平面显像中腹部摄取灶需SPECT/CT精准定位以排除脐周干扰。
核心结论
- 脐部饰品所致局部炎症可在梅克尔憩室显像中表现为假阳性摄取灶。
主要发现
- 动态平面显像示中腹部渐增性摄取灶,提示梅克尔憩室。
- SPECT/CT将摄取灶定位于脐周区域。
- 摄取灶原因考虑为脐部饰品所致局部炎症。
临床怎么用
- 梅克尔憩室显像前应排查脐部饰品等可能干扰因素,必要时结合SPECT/CT定位。
局限性
- 单病例报告,无法推广至所有患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
An 18-year-old woman presented to the emergency department for bloody stools. A CT scan of the abdomen ruled out intussusception. Meckel's scan was ordered to rule for Meckel's diverticulum before upper endoscopy and colonoscopy. After proper pretreatment with H2 blocker, Tc-pertechnetate Meckel's scan was performed. Dynamic planar imaging revealed a focus of gradual increase in uptake in midabdomen suggestive of Meckel's diverticulum. A SPECT/CT was done to localize the focus of uptake. Surprisingly, the focus of uptake localized to the periumbilical region on SPECT/CT images. The cause of uptake could be due to local inflammation from umbilical ornamentation.
引用
- Pillenahalli Maheshwarappa R, Menda Y. Potential False-Positive Meckel's Scan Caused by Umbilical Ornamentation. Clin Nucl Med. 2020. PMID: 32701810. doi:10.1097/RLU.0000000000003211
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。