SPECT/CT:站在巨人肩上,是时候伸手摘星了!
硬件出现固态数字系统、钨基新型准直器、高端多层CT及环形机架多探测器全身系统;新型SPECT放射性药物与核素对推动诊疗一体化,精准医学与放射性核素治疗剂量学需求将驱动其应用。
要点
- SPECT/CT从衰减校正演进至绝对示踪剂摄取定量。
- 固态数字探测器、钨基准直器与环形全身系统提升灵敏度和分辨率。
- 新型SPECT放射性药物及核素对支持诊疗一体化与剂量学。
主要发现
- SPECT/CT结合SPECT诊断灵敏度与CT解剖细节,早期用于SPECT重建衰减校正,后发展至绝对示踪剂摄取定量。
- SPECT硬件出现固态数字系统、基于钨的新型准直器设计,具有更高灵敏度与分辨率。
- 混合SPECT/CT的CT部分引入高端多层CT,配备迭代重建、金属伪影减少算法与双能能力。
- 全身SPECT/CT出现环形机架配备多个可移动探测器围绕患者的设计。
- 新型SPECT放射性药物、螯合剂与 prosthetic groups 及创新SPECT核素对已可用于放射性标记并具诊疗一体化潜力。
临床怎么用
- 精准医学与放射性核素治疗剂量学对准确性的需求,可能驱动SPECT/CT在近未来更广泛应用。
- SPECT/CT在骨科等领域的临床应用扩展提供新机会。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Twenty years ago, SPECT/CT became commercially available, combining the strengths of both techniques: the diagnostic sensitivity of SPECT and the anatomic detail of CT. Other benefits initially included attenuation correction of SPECT reconstructions, ultimately evolving to correction techniques that would enable absolute tracer uptake quantification. Recent developments in SPECT hardware include solid-state digital systems with higher sensitivity and resolution, using novel collimator designs based on tungsten. Similar advances in CT technology have been introduced in hybrid SPECT/CT systems, replacing low-end x-ray tubes with high-end multislice CT scanners equipped with iterative reconstruction, metal artifact reduction algorithms, and dual-energy capabilities. More recently, the design of whole-body SPECT/CT systems has taken another major leap with the introduction of a ring-shaped gantry equipped with multiple movable detectors surrounding the patient. These exciting developments have fueled efforts to develop novel SPECT radiopharmaceuticals, creating new chelators and prosthetic groups for radiolabeling. Innovative SPECT radionuclide pairs have now become available for radiolabeling with the potential for use as theranostic agents. The growth of precision medicine and the associated need for accurate radionuclide treatment dosimetry will likely drive the use of SPECT/CT in the near future. In addition, expanding clinical applications of SPECT/CT in other areas such as orthopedics offer exciting opportunities. Although it is true that the SPECT/CT ecosystem has seen several challenges during its development over the past 2 decades, it is now a feature-rich and mature tool ready for clinical prime time.
引用
- Van den Wyngaert T, Elvas F, De Schepper S, et al. SPECT/CT: Standing on the Shoulders of Giants, It Is Time to Reach for the Sky! J Nucl Med. 2020. PMID: 32620702. doi:10.2967/jnumed.119.236943
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。