腺苷负荷PET/MR心肌灌注显像中心肌蠕动所致配准不良伪影

Myocardial creep-induced misalignment artifacts in PET/MR myocardial perfusion imaging.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-07-18

研究纳入28名志愿者在混合PET/MR上行腺苷负荷与静息13N-氨水心肌灌注显像,评估MRAC与PET数据配准不良的影响。负荷与静息分别有25个(89.3%)和12个(42.9%)PET数据集需重新配准,未校正图像的SRS、SSS、SDS均显著高于校正后图像(均p<0.05)。SDS差异与心肌蠕动量呈中度显著相关(r=0.541,p=0.005),提示心肌蠕动可能导致假阳性。

要点

  • 腺苷负荷PET/MR心肌灌注显像中MRAC与PET数据配准不良常见,负荷期89.3%数据集需重新配准。
  • 未校正配准的SRS、SSS、SDS均显著高于校正后图像(均p<0.05)。
  • SDS差异与心肌蠕动量呈中度显著相关(r=0.541,p=0.005)。

核心结论

  • 在混合PET/MR设备上行腺苷负荷心肌灌注显像时,MRAC与PET数据集配准不良常见,可能导致假阳性 findings 增加。
  • 作者认为心肌蠕动可能在很大程度上解释这种配准不良,并提示应仔细审查和校正PET/MRAC数据。

研究设计与样本

  • 28名志愿者在PET/MR上行腺苷负荷与静息13N-氨水心肌灌注显像,采集Dixon序列生成MRAC图。
  • 重建原始未移位PET图像后检查MRAC与PET数据的心脏空间配准不良,必要时手动调整配准后重建第二套移位PET图像。
  • 比较移位与未移位PET图像的SRS、SSS、SDS,并测量腺苷输注终止后心脏的颅侧移动量(即心肌蠕动)。

主要发现

  • 负荷PET数据集需重新配准25个(89.3%),静息PET数据集需重新配准12个(42.9%)。
  • 未移位图像SRS中位数6(IQR=4-7)、SSS中位数12(IQR=7-18)、SDS中位数8(IQR=2-11)。
  • 移位图像SRS中位数2(IQR=1-6)、SSS中位数4(IQR=7-18)、SDS中位数1(IQR=0-2)。
  • 未移位图像SRS、SSS、SDS均显著高于移位图像(均p<0.05)。
  • SDS差异与心肌蠕动量呈中度显著相关(r=0.541,p=0.005)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Misalignment between positron emission tomography (PET) datasets and attenuation correction (AC) maps is a potential source of artifacts in myocardial perfusion imaging (MPI). We assessed the impact of adenosine on the alignment of AC maps derived from magnetic resonance (MR) and PET datasets during MPI on a hybrid PET/MR scanner. METHODS: Twenty-eight volunteers underwent adenosine stress and rest 13N-ammonia MPI on a PET/MR. We acquired Dixon sequences for the creation of MRAC maps. After reconstruction of the original non-shifted PET images, we examined MRAC and PET datasets for cardiac spatial misalignment and, if necessary, reconstructed a second set of shifted PET images after manually adjusting co-registration. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were compared between shifted and non-shifted PET images. Additionally, we measured the amount of cranial movement of the heart (i.e., myocardial creep) after termination of adenosine infusion. RESULTS: Realignment was necessary for 25 (89.3%) stress and 12 (42.9%) rest PET datasets. Median SRS, SSS, and SDS of the non-shifted images were 6 (IQR = 4-7), 12 (IQR = 7-18), and 8 (IQR = 2-11), respectively, and of the shifted images 2 (IQR = 1-6), 4 (IQR = 7-18), and 1 (IQR = 0-2), respectively. All three scores were significantly higher in non-shifted versus shifted images (all p < 0.05). The difference in SDS correlated moderately but significantly with the amount of myocardial creep (r = 0.541, p = 0.005). CONCLUSION: Misalignment of MRAC and PET datasets commonly occurs during adenosine stress MPI on a hybrid PET/MR device, potentially leading to an increase in false-positive findings. Our results suggest that myocardial creep may substantially account for this and prompt for a careful review and correction of PET/MRAC data.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. von Felten E, Benetos G, Patriki D, et al. Myocardial creep-induced misalignment artifacts in PET/MR myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2020. PMID: 32681446. doi:10.1007/s00259-020-04956-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。