基于18F-FDG PET/CT的影像组学模型鉴别表现为磨玻璃结节的早期浸润性肺腺癌生长模式的价值
本研究纳入91例I期患者的93个磨玻璃结节,提取PET和CT影像组学特征构建模型,用于预测早期浸润性腺癌的中高风险生长模式。联合模型AUC为0.804(95%CI 0.699-0.895),决策曲线显示其临床价值高于单独影像组学评分和CT磨玻璃成分衰减值。
要点
- 研究纳入93个磨玻璃结节,分为贴壁型组18个和腺泡-乳头型组75个。
- 联合模型AUC为0.804(95%CI 0.699-0.895),与CT磨玻璃成分衰减值比较差异未达统计学显著(P=0.109)。
- 联合模型决策曲线在筛选中高风险生长模式目的下显示更高临床价值。
核心结论
- 基于PET/CT的影像组学模型在预测早期浸润性腺癌中高风险生长模式方面表现良好,为风险分层、临床管理和个体化治疗提供了有用方法。
研究设计与样本
- 研究纳入91例I期患者的93个磨玻璃结节,均为术前行18F-FDG PET/CT扫描并接受组织病理学检查者。
- 使用LIFEx软件提取52个PET和49个CT影像组学特征,采用LASSO算法筛选特征并构建影像组学标签。
- 采用ROC曲线比较常规CT参数、影像组学标签及两者联合的预测性能,并基于常规CT指标和影像组学评分构建列线图。
主要发现
- 磨玻璃结节分为贴壁型组18个和腺泡-乳头型组75个。
- 筛选出4个影像组学特征(PET 2个、CT 2个)用于计算影像组学评分,其AUC为0.790,与CT磨玻璃成分衰减值的AUC 0.675比较无显著差异。
- 影像组学评分联合边缘(联合模型)后AUC增至0.804(95%CI 0.699-0.895),但与CT磨玻璃成分衰减值比较未达统计学显著(P=0.109)。
- 联合模型的决策曲线在筛选中高风险生长模式目的下显示比影像组学评分和CT磨玻璃成分衰减值更高的临床价值。
关键数值与推荐
- 影像组学评分AUC为0.790,CT磨玻璃成分衰减值AUC为0.675。
- 联合模型AUC为0.804(95%CI 0.699-0.895),与CT磨玻璃成分衰减值比较P=0.109。
临床怎么用
- 原文结论认为该模型为风险分层、临床管理和个体化治疗提供了有用方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To establish and validate 18F-fluorodeoxyglucose (18F-FDG) PET/CT-based radiomics model and use it to predict the intermediate-high risk growth patterns in early invasive adenocarcinoma (IAC). METHODS: Ninety-three ground-glass nodules (GGNs) from 91 patients with stage I who underwent a preoperative 18F-FDG PET/CT scan and histopathological examination were included in this study. The LIFEx software was used to extract 52 PET and 49 CT radiomic features. The least absolute shrinkage and selection operator (LASSO) algorithm was used to select radiomic features and develop radiomics signatures. We used the receiver operating characteristics curve (ROC) to compare the predictive performance of conventional CT parameters, radiomics signatures, and the combination of these two. Also, a nomogram based on conventional CT indicators and radiomics signature score (rad-score) was developed. RESULTS: GGNs were divided into lepidic group (n = 18) and acinar-papillary group (n = 75). Four radiomic features (2 for PET and 2 for CT) were selected to calculate the rad-score, and the area under the curve (AUC) of rad-score was 0.790, which was not significantly different as the attenuation value of the ground-glass opacity component on CT (CTGGO) (0.675). When rad-score was combined with edge (joint model), the AUC increased to 0.804 (95% CI [0.699-0.895]), but which was not significantly higher than CTGGO (P = 0.109). Furthermore, the decision curve of joint model showed higher clinical value than rad-score and CTGGO, especially under the purpose of screening for intermediate-high risk growth patterns. CONCLUSION: PET/CT-based radiomics model shows good performance in predicting intermediate-high risk growth patterns in early IAC. This model provides a useful method for risk stratification, clinical management, and personalized treatment.
引用
- Shao X, Niu R, Shao X, et al. Value of 18F-FDG PET/CT-based radiomics model to distinguish the growth patterns of early invasive lung adenocarcinoma manifesting as ground-glass opacity nodules. EJNMMI Res. 2020. PMID: 32661639. doi:10.1186/s13550-020-00668-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。