文献速递肿瘤 PET/CT心脏核医学

重度肺气肿中正电子发射断层扫描通气-灌注匹配与CT密度测定的相关性

Correlation of positron emission tomography ventilation-perfusion matching with CT densitometry in severe emphysema.
PubMed 文献 · EJNMMI Res · 2020-07-28

研究纳入2015年3月至2018年3月间接受支气管镜肺减容评估的14例连续重度肺气肿患者,行镓-68通气/灌注PET-CT(68Ga-VQ/PET-CT)肺叶功能定位及CT密度测定。结果显示CT密度测定与肺叶灌注仅弱相关(R2=0.13),与通气无相关(R2=0.04);上叶密度测定与V/Q单位中度相关(R2=0.67),下叶反映生理功能较差(R2=0.19)。作者认为68Ga-VQ/PET-CT可提供CT密度测定未显现的生理信息,需进一步研究其不一致发现能否提供预后信息或改善患者管理。

要点

  • CT密度测定与肺叶灌注仅弱相关(R2=0.13),与通气无相关(R2=0.04)。
  • 上叶密度测定与V/Q单位中度相关(R2=0.67),下叶反映生理功能较差(R2=0.19)。
  • 68Ga-VQ/PET-CT可提供通气和灌注细节及匹配缺损等CT密度测定未显现的生理信息。

核心结论

  • 68Ga-VQ/PET-CT评估肺叶功能可提供CT密度测定未显现的生理信息,如通气和灌注细节及匹配缺损。
  • 需进一步研究68Ga-VQ/PET-CT的不一致发现能否提供预后信息或用于调整患者管理并改善结局。

研究设计与样本

  • 2015年3月至2018年3月间连续纳入14例接受支气管镜肺减容评估的重度肺气肿患者。
  • 患者接受68Ga-VQ/PET-CT肺叶功能定位评估及CT密度测定,分析CT密度测定与68Ga-VQ/PET-CT各肺叶功能参数的相关性。

主要发现

  • CT密度测定评估的肺气肿与肺叶灌注仅弱相关(R2=0.13),与通气无相关(R2=0.04)。
  • CT密度测定与上叶V/Q单位中度相关(R2=0.67),对下叶生理功能反映较差(R2=0.19)。
  • CT密度测定评估的肺气肿严重度与各肺叶正常V/Q单位比例及匹配的V/Q缺损中度相关。

局限性

  • 需进一步研究68Ga-VQ/PET-CT的不一致发现能否提供预后信息或用于调整患者管理并改善结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Emphysema severity is frequently measured on CT via densitometry. Correlation with scintigraphic and spirometric functional measures of ventilation or perfusion varies widely, and no prior study has evaluated correlation between densitometry and lobar ventilation/perfusion in patients with severe emphysema. The aim of this study was to evaluate the utility and findings of gallium-68 (68Ga) ventilation/perfusion positron emission tomography-CT (68Ga-VQ/PET-CT) in severe emphysema assessment. METHODS: Fourteen consecutive patients undergoing evaluation for bronchoscopic lung volume reduction between March 2015 and March 2018 underwent 68Ga-VQ/PET-CT assessment for lobar functional lung mapping, in addition to CT densitometry. Correlations between CT densitometry and 68Ga-VQ/PET-CT parameters for individual lobar lung function were sought. RESULTS: CT densitometry assessment of emphysema correlated only weakly (R2 = 0.13) with lobar perfusion and was not correlated with ventilation (R2 = 0.04). Densitometry was moderately (R2 = 0.67) correlated with V/Q units in upper lobes, though poorly reflected physiological function in lower lobes (R2 = 0.19). Emphysema severity, as measured by CT densitometry, was moderately correlated with proportion of normal V/Q units and matched V/Q defects in individual lobes. CONCLUSIONS: Assessment of lobar pulmonary function by 68Ga-VQ/PET-CT provides physiologic information not evident on CT densitometry such as ventilation and perfusion specifics and matched defects. Further research is needed to see if the discordant findings on 68Ga-VQ/PET-CT provide prognostic information or can be used to modify patient management and improve outcomes.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Bonney A, Wagner CA, Siva S, et al. Correlation of positron emission tomography ventilation-perfusion matching with CT densitometry in severe emphysema. EJNMMI Res. 2020. PMID: 32725552. doi:10.1186/s13550-020-00672-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。