混合PET/冠状动脉CT评估的定量心肌灌注82Rb-PET:正常值与诊断效能
研究纳入357例连续患者,用混合PET/冠状动脉CT计算全局及区域负荷心肌血流量(sMBF)、静息心肌血流量和心肌血流储备(MFR),并提供正常值。全局sMBF识别缺血和严重缺血的准确性优于MFR,全局sMBF排除心肌缺血的最佳阈值为3.5 mL·g⁻¹·min⁻¹,该阈值排除CAD的阴性预测值与CCTA相似(96%),sMBF高于参考值时或可省略静息扫描。
要点
- 正常患者全局sMBF和MFR高于CAD患者,但与无阻塞性狭窄患者无显著差异。
- sMBF识别缺血和严重缺血的AUC分别为0.74和0.88,均优于MFR。
- 全局sMBF排除心肌缺血的最佳阈值为3.5 mL·g⁻¹·min⁻¹。
核心结论
- 研究提供了定量心肌灌注的正常值,全局sMBF诊断准确性高于MFR。
- 82Rb-PET/CT上sMBF阈值3.5 mL·g⁻¹·min⁻¹排除CAD的阴性预测值与CCTA相似(96%)。
- sMBF高于参考值的患者或可省略静息扫描。
研究设计与样本
- 研究纳入357例连续患者,行82Rb-PET/CT及整合的CT冠状动脉造影(CCTA)。
- 患者分为正常(无狭窄)、非阻塞性狭窄(<50%)和CAD(≥50%)三组。
- 计算全局及区域负荷MBF(sMBF)、静息MBF和心肌血流储备(MFR)。
- 缺血定义为SDS≥2,严重缺血定义为SDS≥7。
主要发现
- 正常患者全局sMBF高于CAD患者(3.61±0.71 vs 3.04±0.77,P<0.0001)。
- 正常患者全局MFR高于CAD患者(3.08±0.84 vs 2.68±0.79,P=0.0001)。
- 正常患者与无阻塞性狭窄患者全局sMBF无显著差异(3.61±0.71 vs 3.43±0.69,P=0.052)。
- 正常患者与无阻塞性狭窄患者全局MFR无显著差异(3.08±0.84 vs 2.99±0.82,P=0.45)。
- sMBF识别缺血的AUC为0.74,优于MFR的0.62(P=0.003);识别严重缺血的AUC为0.88,优于MFR的0.78(P=0.012)。
关键数值与推荐
- 全局sMBF排除心肌缺血的最佳阈值为3.5 mL·g⁻¹·min⁻¹。
- 缺血定义为SDS≥2,严重缺血定义为SDS≥7。
- sMBF阈值3.5 mL·g⁻¹·min⁻¹排除CAD的阴性预测值为96%。
临床怎么用
- 作者认为,全局sMBF诊断准确性高于MFR。
- 作者指出,使用sMBF阈值3.5 mL·g⁻¹·min⁻¹排除CAD的阴性预测值与CCTA相似(96%)。
- 作者提出,sMBF高于参考值的患者或可省略静息扫描。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We aimed to assess normal values for quantified myocardial blood flow (MBF) on a hybrid PET/coronary-CT scanner and to test their diagnostic performance in patients with suspected CAD. MATERIALS AND METHODS: Patients underwent 82Rb-PET/CT and integrated CT-based coronary angiography (CCTA) and were classified as normal (no stenosis), with non-obstructive stenosis (< 50%) and with CAD (≥ 50%). Global and regional stress MBF (sMBF), rest MBF and myocardial flow reserve (MFR) were calculated. Ischemia was defined as SDS ≥ 2, severe ischemia as SDS ≥ 7. RESULTS: 357 consecutive patients were included. Global sMBF and MFR were higher in normal patients than in patients with CAD (3.61 ± 0.71 vs 3.04 ± 0.77, P < 0.0001; 3.08 ± 0.84 vs 2.68 ± 0.79, P = 0.0001), but not different compared to patients with non-obstructive stenosis (3.61 ± 0.71 vs 3.43 ± 0.69, P = 0.052; 3.08 ± 0.84 vs 2.99 ± 0.82, P = 0.45). sMBF yielded superior accuracy over MFR in identifying both ischemia (AUC 0.74 vs 0.62, P = 0.003) and severe ischemia (AUC 0.88 vs 0.78, P = 0.012). Optimal threshold for global sMBF to rule out myocardial ischemia was 3.5 mL g-1 min-1. CONCLUSIONS: Normal quantitative values are provided. Global sMBF provided higher diagnostic accuracy than MFR. Using sMBF-threshold of 3.5 mL·g-1·min-1 on 82Rb-PET/CT yielded similar NPV (96%) as CCTA to rule out CAD. Hence, resting scan could be omitted in patients with sMBF values above reference.
引用
- Freitag MT, Bremerich J, Wild D, et al. Quantitative myocardial perfusion 82Rb-PET assessed by hybrid PET/coronary-CT: Normal values and diagnostic performance. J Nucl Cardiol. 2020. PMID: 32676910. doi:10.1007/s12350-020-02264-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。