文献速递肿瘤 PET/CT心脏核医学

18F-FDG PET/CT联合胸部增强CT评估成人原发性心脏肿瘤

Combined PET/CT with thoracic contrast-enhanced CT in assessment of primary cardiac tumors in adult patients.
PubMed 文献 · EJNMMI Res · 2020-07-06

该回顾性研究纳入46例原发性心脏肿瘤患者,评估18F-FDG PET/CT联合胸部增强CT(CECT)与单独CECT或PET/CT相比的诊断价值;联合两种模态将特异性从79%提高至93%、阳性预测值从73%提高至89%、诊断准确率从85%提高至93%,与单独PET/CT或单独CECT相比差异有统计学意义(P=0.034和P=0.026)。

要点

  • 超过半数(16/29)良性肿瘤表现为轻度18F-FDG摄取。
  • 良性与恶性肿瘤的18F-FDG摄取及绝对强化程度差异有统计学意义(P<0.001)。
  • 联合最佳SUVmax截断值可达到94%灵敏度、100%特异性、97%阴性预测值、100%阳性预测值和98%准确率。

核心结论

  • 联合18F-FDG PET/CT与胸部CECT在检测肿瘤方面较单独CECT或PET/CT显著提高特异性和准确率,该联合影像有助于鉴别良性与恶性肿块。

研究设计与样本

  • 回顾性纳入46例连续诊断为原发性心脏肿瘤的成人患者,所有患者均在活检或手术前接受18F-FDG PET/CT及随后胸部CECT,进行视觉定性解读与定量分析并评估诊断效能。

主要发现

  • 超过半数(16/29)良性肿瘤表现为轻度18F-FDG摄取。
  • 良性与恶性肿瘤的18F-FDG摄取及绝对强化程度差异有统计学意义(P<0.001)。
  • 联合两种模态将特异性从79%提高至93%、阳性预测值从73%提高至89%、诊断准确率从85%提高至93%。
  • 单独PET/CT或单独胸部CECT与联合模态之间差异有统计学意义(分别为P=0.034和P=0.026)。
  • 联合最佳SUVmax截断值生成94%灵敏度、100%特异性、97%阴性预测值、100%阳性预测值和98%准确率。

关键数值与推荐

  • 联合两种模态:特异性93%、阳性预测值89%、诊断准确率93%。
  • 单独CECT或PET/CT:特异性79%、阳性预测值73%、诊断准确率85%。
  • 联合最佳SUVmax截断值:灵敏度94%、特异性100%、阴性预测值97%、阳性预测值100%、准确率98%。

临床怎么用

  • 作者认为联合18F-FDG PET/CT与胸部CECT可有效鉴别恶性与良性肿块。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: 18F-FDG PET/CT is a key molecular imaging modality to noninvasively assess and differentiate benign and malignant cardiac tumors. However, few benign cardiac tumors can be characterized by increased 18F-FDG uptake, which makes differential diagnosis difficult. This study sought to retrospectively evaluate whether combined 18F-FDG PET/CT with thoracic contrast-enhanced CT (CECT) helps in assessing primary cardiac tumors in adult patients, compared with CECT or PET/CT alone. METHODS: Forty-six consecutive patients who were diagnosed as primary cardiac tumors were enrolled. All patients underwent 18F-FDG PET/CT followed by thoracic CECT before biopsy or surgery. Visual qualitative interpretation and quantitative analysis were performed, and diagnostic performance was evaluated. RESULTS: More than half (16/29) of benign tumors exhibited with mild 18F-FDG uptake. There were significant differences in 18F-FDG uptake and the degree of absolute enhancement between benign and malignant tumors (P < 0.001). The combination of two modalities improved the specificity from 79 to 93%, the positive predictive value from 73 to 89%, and the accuracy of diagnosis from 85 to 93%. There were significant differences between PET/CT alone or thoracic CECT alone and combined modalities (P = 0.034 and P = 0.026, respectively). The combination with the optimal SUVmax cutoff value generated 94% sensitivity, 100% specificity, 97% negative predictive values, 100% positive predictive values, and 98% accuracy rates. CONCLUSIONS: Combining 18F-FDG PET/C with thoracic CECT significantly improved specificity and accuracy compared to CECT or PET/CT alone in detecting tumors. This combination of diagnostic imaging is effective in differentiating malignant from benign masses.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Liu ET, Sun TT, Dong HJ, et al. Combined PET/CT with thoracic contrast-enhanced CT in assessment of primary cardiac tumors in adult patients. EJNMMI Res. 2020. PMID: 32632639. doi:10.1186/s13550-020-00661-x