文献速递心脏核医学

腹主动脉瘤患者[18F]-NaF PET/CT图像不同定量指标评估

Assessment of different quantification metrics of [18F]-NaF PET/CT images of patients with abdominal aortic aneurysm.
PubMed 文献 · J Nucl Cardiol · 2020-06-17

本研究评估腹主动脉瘤(AAA)[18F]-NaF PET/CT显像中的溢出效应及背景校正(BC)技术对定量准确性的获益。72例数据集采用含点扩散函数(PSF)的OSEM算法重建,比较不同阈值TBR指标在3次与10次迭代下的表现。结果显示TBR50在减少溢出效应与提高CNR间取得最佳平衡。

要点

  • TBRmax对溢出效应最敏感,TBR50最不敏感。
  • 10次迭代较3次迭代减少溢出效应,但CNR降低。
  • TBR50在提高CNR与减少溢出效应间取得最佳平衡。

核心结论

  • TBR50是减少溢出效应并提高CNR的稳健指标。

研究设计与样本

  • 回顾性分析72例腹主动脉瘤患者数据集,采用含点扩散函数的OSEM算法重建[18F]-NaF PET/CT图像。

主要发现

  • 由于骨骼向动脉瘤的溢出效应,AAA与AAAexc之间观察到TBR差异。
  • TBRmax对溢出效应敏感性最高,TBR50敏感性最低。
  • 10次迭代较3次迭代溢出效应减少,但对比噪声比(CNR)降低。
  • TBR50在提高CNR与减少溢出效应间取得最佳平衡。
  • PSF+BC法较PSF降低了TBR对溢出效应的敏感性,尤其在3次迭代时(P值≤0.05)。

关键数值与推荐

  • TBRmax、TBR90、TBR70及TBR50分别对应目标感兴趣区内最大SUV百分比阈值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We aim to assess the spill-in effect and the benefit in quantitative accuracy for [18F]-NaF PET/CT imaging of abdominal aortic aneurysms (AAA) using the background correction (BC) technique. METHODS: Seventy-two datasets of patients diagnosed with AAA were reconstructed with ordered subset expectation maximization algorithm incorporating point spread function (PSF). Spill-in effect was investigated for the entire aneurysm (AAA), and part of the aneurysm excluding the region close to the bone (AAAexc). Quantifications of PSF and PSF+BC images using different thresholds (% of max. SUV in target regions-of-interest) to derive target-to-background (TBR) values (TBRmax, TBR90, TBR70 and TBR50) were compared at 3 and 10 iterations. RESULTS: TBR differences were observed between AAA and AAAexc due to spill-in effect from the bone into the aneurysm. TBRmax showed the highest sensitivity to the spill-in effect while TBR50 showed the least. The spill-in effect was reduced at 10 iterations compared to 3 iterations, but at the expense of reduced contrast-to-noise ratio (CNR). TBR50 yielded the best trade-off between increased CNR and reduced spill-in effect. PSF+BC method reduced TBR sensitivity to spill-in effect, especially at 3 iterations, compared to PSF (P-value ≤ 0.05). CONCLUSION: TBR50 is robust metric for reduced spill-in and increased CNR.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Akerele MI, Mushari NA, Forsythe RO, et al. Assessment of different quantification metrics of [18F]-NaF PET/CT images of patients with abdominal aortic aneurysm. J Nucl Cardiol. 2020. PMID: 32557152. doi:10.1007/s12350-020-02220-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。