深度学习18F-FDG摄取分类可实现弥漫性大B细胞淋巴瘤的总代谢肿瘤体积估算
本研究回顾性分析REMARC试验中301例弥漫性大B细胞淋巴瘤(DLBCL)患者的基线18F-FDG PET/CT,用原型软件(PARS)结合卷积神经网络对高摄取区域分类并估算总代谢肿瘤体积(TMTVPARS),与2名有经验读者测定的TMTVREF比较。TMTVPARS与TMTVREF显著相关(ρ=0.76;P<0.001),分类准确率85%、敏感度80%、特异度88%;两者对无进展生存(PFS)和总生存(OS)均有显著预后价值。结论认为TMTVPARS与专家测量结果一致,深度学习分类可简化TMTV估算。
要点
- TMTVPARS与TMTVREF显著相关(ρ=0.76;P<0.001)。
- 深度学习分类准确率85%、敏感度80%、特异度88%。
- TMTVPARS与TMTVREF对PFS和OS均有显著预后价值(P<0.001)。
核心结论
- TMTVPARS与专家测定的TMTV结果一致,并在DLBCL患者中对PFS和OS显示显著预后价值。
研究设计与样本
- 回顾性分析REMARC试验(NCT01122472)中301例DLBCL患者的基线18F-FDG PET/CT扫描。
主要发现
- TMTVPARS与TMTVREF显著相关(ρ=0.76;P<0.001)。
- 使用PARS平均每例识别24个摄取增高区域,平均每例20个区域被正确分类为不可疑或可疑,分类准确率85%、敏感度80%、特异度88%。
- TMTVPARS对PFS的风险比为2.3,TMTVREF对PFS的风险比为2.6(P<0.001)。
- TMTVPARS对OS的风险比为2.8,TMTVREF对OS的风险比为3.7(P<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Total metabolic tumor volume (TMTV), calculated from 18F-FDG PET/CT baseline studies, is a prognostic factor in diffuse large B-cell lymphoma (DLBCL) whose measurement requires the segmentation of all malignant foci throughout the body. No consensus currently exists regarding the most accurate approach for such segmentation. Further, all methods still require extensive manual input from an experienced reader. We examined whether an artificial intelligence-based method could estimate TMTV with a comparable prognostic value to TMTV measured by experts. Methods: Baseline 18F-FDG PET/CT scans of 301 DLBCL patients from the REMARC trial (NCT01122472) were retrospectively analyzed using a prototype software (PET Assisted Reporting System [PARS]). An automated whole-body high-uptake segmentation algorithm identified all 3-dimensional regions of interest (ROIs) with increased tracer uptake. The resulting ROIs were processed using a convolutional neural network trained on an independent cohort and classified as nonsuspicious or suspicious uptake. The PARS-based TMTV (TMTVPARS) was estimated as the sum of the volumes of ROIs classified as suspicious uptake. The reference TMTV (TMTVREF) was measured by 2 experienced readers using independent semiautomatic software. The TMTVPARS was compared with the TMTVREF in terms of prognostic value for progression-free survival (PFS) and overall survival (OS). Results: TMTVPARS was significantly correlated with the TMTVREF (ρ = 0.76; P < 0.001). Using PARS, an average of 24 regions per subject with increased tracer uptake was identified, and an average of 20 regions per subject was correctly identified as nonsuspicious or suspicious, yielding 85% classification accuracy, 80% sensitivity, and 88% specificity, compared with the TMTVREF region. Both TMTV results were predictive of PFS (hazard ratio, 2.3 and 2.6 for TMTVPARS and TMTVREF, respectively; P < 0.001) and OS (hazard ratio, 2.8 and 3.7 for TMTVPARS and TMTVREF, respectively; P < 0.001). Conclusion: TMTVPARS was consistent with that obtained by experts and displayed a significant prognostic value for PFS and OS in DLBCL patients. Classification of high-uptake regions using deep learning for rapidly discarding physiologic uptake may considerably simplify TMTV estimation, reduce observer variability, and facilitate the use of TMTV as a predictive factor in DLBCL patients.
引用
- Capobianco N, Meignan M, Cottereau AS, et al. Deep-Learning 18F-FDG Uptake Classification Enables Total Metabolic Tumor Volume Estimation in Diffuse Large B-Cell Lymphoma. J Nucl Med. 2020. PMID: 32532925. doi:10.2967/jnumed.120.242412
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。