18F-氟化钠冠状动脉微钙化活动的观察者重复性与扫描间可重复性
本研究旨在建立采用新型半自动方法冠状动脉微钙化活动(CMA)评估冠状动脉18F-氟化钠PET摄取时的观察者重复性与扫描间可重复性。19例多支冠状动脉病变患者接受间隔12±5天的重复PET/CTA显像,在43支冠状动脉中评估CMA。结果显示观察者内、观察者间重复性及扫描间可重复性均优秀(组内相关系数均≥0.991),CMA是冠状动脉粥样硬化活动的可重复、可再现的全局测量指标。
要点
- CMA在观察者内、观察者间及扫描间均显示优秀重复性(组内相关系数均≥0.991)。
- 对冠状动脉18F-NaF摄取存在(CMA>0)或不存在(CMA=0)的判断,观察者内、观察者间及扫描间一致率均为100%。
- 平均CMA为3.12±0.62,所有测量的重复性系数≤10%。
核心结论
- CMA是冠状动脉粥样硬化活动的可重复、可再现的全局测量指标。
研究设计与样本
- 19例多支冠状动脉病变患者接受重复混合PET与计算机断层摄影血管造影(PET/CTA)显像,两次扫描间隔12±5天。
- 在43支冠状动脉中评估CMA,CMA定义为整个冠状动脉树中超过背景SUV 2个标准差的整合标准化摄取值(SUV)。
主要发现
- 观察者内、观察者间重复性及扫描间可重复性的组内相关系数均≥0.991。
- 对冠状动脉18F-NaF摄取存在(CMA>0)或不存在(CMA=0)的判断,观察者内、观察者间及扫描间一致率均为100%。
- 平均CMA为3.12±0.62,所有测量的重复性系数≤10%:观察者内分别为每血管0.24和每患者0.22,观察者间分别为每血管0.30和每患者0.29,扫描间分别为每血管0.33和每患者0.32。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We aimed to establish the observer repeatability and interscan reproducibility of coronary 18F-sodium-fluoride positron emission tomography (PET) uptake using a novel semi-automated approach, coronary microcalcification activity (CMA). METHODS: Patients with multivessel coronary artery disease underwent repeated hybrid PET and computed tomography angiography (CTA) imaging (PET/CTA). CMA was defined as the integrated standardized uptake values (SUV) in the entire coronary tree exceeding 2 standard deviations above the background SUV. Coefficients of repeatability between the same observer (intraobserver repeatability), between 2 observers (interobserver repeatability) and coefficient of reproducibility between 2 scans (interscan reproducibility), were determined at vessel and patient level. RESULTS: In 19 patients, CMA was assessed twice in 43 coronary vessels on two PET/CT scans performed 12 ± 5 days apart. There was excellent intraclass correlation for intraobserver and interobserver repeatability as well as interscan reproducibility (all ≥ 0.991). There was 100% intraobserver, interobserver and interscan agreement for the presence (CMA > 0) or absence (CMA = 0) of coronary18F-NaF uptake. Mean CMA was 3.12 ± 0.62 with coefficients of repeatability of ≤ 10% for all measures: intraobserver 0.24 and 0.22, interobserver 0.30 and 0.29 and interscan 0.33 and 0.32 at a per-vessel and per-patient level, respectively. CONCLUSIONS: CMA is a repeatable and reproducible global measure of coronary atherosclerotic activity.
引用
- Tzolos E, Kwiecinski J, Lassen ML, et al. Observer repeatability and interscan reproducibility of 18F-sodium fluoride coronary microcalcification activity. J Nucl Cardiol. 2020. PMID: 32529531. doi:10.1007/s12350-020-02221-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。