左束支传导阻滞患者心肌灌注SPECT所见的灌注缺损在多大程度上与心肌梗死、心电图特征及心肌室壁运动相关?
纳入23例左束支传导阻滞(LBBB)患者,同期行心肌灌注SPECT(MPS)与心脏磁共振(CMR)。MPS示典型LBBB模式(缺损+组,n=13)者室间隔壁厚度略低于侧壁(5.6±1.1 vs 6.0±1.3 mm,P=0.03),室间隔运动障碍及侧壁运动增强节段比例高于缺损-组(P=0.006和P=0.004),径向应变减低与示踪剂摄取减低相关(R=0.37,P<0.001),纤维化区域与灌注缺损不匹配,心电图变量无差异。
要点
- MPS典型LBBB模式者室间隔壁厚度略低于侧壁(5.6±1.1 vs 6.0±1.3 mm,P=0.03),缺损-组无此差异。
- 缺损+组室间隔运动障碍及侧壁运动增强节段比例高于缺损-组(P=0.006和P=0.004)。
- 心肌径向应变减低与MPS示踪剂摄取减低相关(R=0.37,P<0.001),纤维化区域与灌注缺损不匹配。
核心结论
- 部分LBBB患者MPS区域示踪剂摄取异质性可能与局部心肌运动障碍、室壁增厚及室壁厚度相关,而非负荷诱发缺血、心肌纤维化或特定心电图特征。
研究设计与样本
- 纳入23例(女性9例)LBBB患者,均行MPS与CMR检查。
- MPS示踪剂摄取经视觉判读分为典型LBBB模式(缺损+组,n=13)与非典型(缺损-组,n=10),并进行定量分析。
- CMR评估室壁厚度、室壁运动(视觉评估及特征追踪区域径向应变)及心肌纤维化存在与位置;心电图分析QRS时限及严格LBBB标准。
主要发现
- 缺损+组室间隔壁厚度略低于侧壁(5.6±1.1 vs 6.0±1.3 mm,P=0.03),缺损-组无差异(5.6±1.0 vs 5.6±0.9 mm,P=0.84)。
- 缺损+组室间隔运动障碍节段比例高于缺损-组(P=0.006),侧壁运动增强节段比例亦高于缺损-组(P=0.004)。
- 心肌径向应变减低与MPS示踪剂摄取减低相关(R=0.37,P<0.001)。
- 纤维化区域与MPS示踪剂摄取缺损区域不匹配。
- 心电图变量未见差异。
关键数值与推荐
- MPS视觉判读分为典型LBBB模式(Defect+,n=13)与非典型(Defect-,n=10)。
- 室间隔与侧壁壁厚度比较:缺损+组5.6±1.1 vs 6.0±1.3 mm(P=0.03);缺损-组5.6±1.0 vs 5.6±0.9 mm(P=0.84)。
- 径向应变与示踪剂摄取相关R=0.37,P<0.001。
- 室间隔运动障碍节段比例缺损+组高于缺损-组(P=0.006);侧壁运动增强节段比例缺损+组高于缺损-组(P=0.004)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: We investigated if uptake pattern on myocardial perfusion SPECT (MPS) in patients with left bundle branch block (LBBB) is related to myocardial fibrosis, myocardial wall motion, and electrocardiography (ECG) characteristics. METHODS: Twenty-three patients (9 women) with LBBB, examined with MPS and cardiac magnetic resonance (CMR), were included. Tracer uptake on MPS was classified by visual interpretation as typical LBBB pattern (Defect+, n = 13) or not (Defect-, n = 10) and quantitatively. CMR images were evaluated for wall thickness and for myocardial wall motion both by visual assessment and by regional myocardial radial strain from feature tracking, and for presence and location of myocardial fibrosis. ECGs were analyzed regarding QRS duration and the presence of strict criteria for LBBB. RESULTS: Wall thickness was slightly lower in the septum compared to the lateral wall in Defect+ patients (5.6 ± 1.1 vs 6.0 ± 1.3 mm, P = 0.03) but not in Defect- patients (5.6 ± 1.0 vs 5.6 ± 0.9 mm, P = 0.84). Defect+ patients showed a larger proportion of dyskinetic segments in the septum and hyperkinetic segments in the lateral wall compared to Defect- patients (P = 0.006 and P = 0.004, respectively). Decreased myocardial radial strain was associated with decreased tracer uptake by MPS (R = 0.37, P < 0.001). Areas of fibrosis did not match areas with uptake defect on MPS. No differences in ECG variables were seen. CONCLUSION: The heterogeneous regional tracer uptake in some patients with LBBB is related to underlying regional myocardial dyskinesia, wall thickening, and wall thickness rather than stress-induced ischemia, myocardial fibrosis, or specific ECG characteristics.
引用
- Hedeer F, Ostenfeld E, Hedén B, et al. To what extent are perfusion defects seen by myocardial perfusion SPECT in patients with left bundle branch block related to myocardial infarction, ECG characteristics, and myocardial wall motion? J Nucl Cardiol. 2020. PMID: 32451797. doi:10.1007/s12350-020-02180-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。