CZT-SPECT定量心肌灌注储备:与82铷PET成像的头对头比较
在25例有冠状动脉造影数据的疑似或已知冠心病患者中,用动态CZT-SPECT和82Rb-PET测量心肌血流量与灌注储备并比较预测阻塞性冠心病的准确性。CZT-SPECT所得充血性MBF和MPR高于PET,MPR相关性中等(r=0.56,P<.01)。CZT-SPECT识别PET异常MPR的AUC为0.85,MPR界值2.5时敏感度86%、特异度73%、准确率80%。
要点
- CZT-SPECT测得的充血性MBF和MPR高于82Rb-PET,二者MPR相关性中等(r=0.56,P<.01)。
- CZT-SPECT以MPR界值2.5识别PET异常MPR,敏感度86%、特异度73%、准确率80%,AUC 0.85。
- 识别阻塞性冠心病的区域MPR AUC:CZT-SPECT 0.83 vs PET 0.84(P=.90),诊断准确性相当(P=.62)。
核心结论
- CZT-SPECT所得的充血性MBF和MPR高于82Rb-PET,两种方法间相关性中等。
- CZT-SPECT对识别阻塞性冠心病显示出良好的诊断准确性。
- 作者认为这些发现可能鼓励使用该新技术以改善风险分层和患者管理。
研究设计与样本
- 25例有冠状动脉造影数据的疑似或已知冠心病患者接受了99mTc-甲氧基异丁基异腈CZT-SPECT和82Rb-PET心脏成像。
- 用两种方法计算负荷与静息MBF及MPR并进行比较,还用受试者工作特征曲线评估诊断准确性。
主要发现
- CZT-SPECT所得基线MBF与PET相似,但充血性MBF和MPR值高于PET。
- 两种方法的MPR相关性中等(r=0.56,P<.01)。
- CZT-SPECT的MPR识别PET所测MPR减低的能力良好,曲线下面积为0.85。
- 识别阻塞性冠心病的区域MPR曲线下面积:CZT-SPECT为0.83,PET为0.84(P=.90)。
- 使用各自界值时CZT-SPECT与PET的诊断准确性相当(P=.62)。
关键数值与推荐
- CZT-SPECT识别PET异常MPR的MPR界值为2.5,敏感度86%、特异度73%、准确率80%。
- CZT-SPECT识别阻塞性冠心病时,区域MPR为2.1在敏感度与特异度间提供最佳平衡。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We measured myocardial blood flow (MBF) and perfusion reserve (MPR) by dynamic CZT-SPECT and 82Rb-PET in patients with suspected or known coronary artery disease (CAD) and compared the accuracy of the two methods in predicting obstructive CAD. METHODS: Twenty-five patients with available coronary angiography data underwent 99mTc-sestamibi CZT-SPECT and 82Rb-PET cardiac imaging. Stress and rest MBF and MPR were calculated by both methods and compared. Diagnostic accuracies of CZT-SPECT and PET were also assessed using a receiver-operator-characteristic curve. RESULTS: CZT-SPECT yielded similar baseline MBF, but higher hyperemic MBF and MPR values compared to PET. There was a modest correlation between the two methods for MPR (r = 0.56, P < .01). MPR by CZT-SPECT showed a good ability in identify a reduced MPR by PET, with an area under the curve of 0.85. A MPR cut-off of 2.5 was identified by CZT-SPECT for detection of abnormal MPR by PET, with a sensitivity, specificity and accuracy of 86%, 73% and 80%. The area under the curve for the identification of obstructive CAD by regional MPR were 0.83 for CZT-SPECT and 0.84 for PET (P = .90). At CZT-SPECT, a regional MPR of 2.1 provided the best trade-off between sensitivity and specificity for identifying obstructive CAD. Diagnostic accuracy of CZT-SPECT and PET using respective cut-off values was comparable (P = .62). CONCLUSION: Hyperemic MBF and MPR values obtained by CZT-SPECT are higher than those measured by 82Rb-PET imaging, with a moderate correlation between the two methods. CZT-SPECT shows good diagnostic accuracy for the identification of obstructive CAD. These findings may encourage the use of this new technique to a better risk stratification and patient management.