文献速递心脏核医学

硅光电倍增器PET在铷-82心肌灌注显像中的价值

Value of SiPM PET in myocardial perfusion imaging using Rubidium-82.
PubMed 文献 · J Nucl Cardiol · 2020-05-14

前瞻性纳入30例患者,分别接受D690 PMT PET与Vereos SiPM PET静息及瑞加诺生负荷铷-82心肌灌注显像。SiPM PET图像质量改善(P=0.03),但缺损判读、判读者信心及心肌血流量与心肌血流储备均无显著差异,作者认为SiPM PET是可靠的铷-82心肌灌注显像技术。

要点

  • Vereos SiPM PET图像质量较D690 PMT PET改善(P=0.03)。
  • 两系统间缺损判读与判读者信心无显著差异(P>0.50)。
  • 静息、负荷心肌血流量及心肌血流储备均无显著差异。

核心结论

  • SiPM PET较PMT PET提供改善的图像质量,缺损判读、判读者信心与绝对血流测量在两系统间相当,SiPM PET是铷-82心肌灌注显像的可靠技术。

研究设计与样本

  • 前瞻性纳入30例患者,先后在D690 PMT PET(GE Healthcare)和Vereos SiPM PET(Philips Healthcare)上行静息及瑞加诺生负荷铷-82心肌灌注显像,两次检查间隔三周内,由两名专家判读图像质量并评估可能的缺损。

主要发现

  • Vereos较D690图像质量改善(P=0.03)。
  • 图像质量分级:Vereos为一般20%、良好60%、优秀20%,D690为一般10%、良好50%、优秀40%。
  • 缺损判读与判读者信心在D690与Vereos间无差异(P>0.50)。
  • 静息心肌血流量(P≥0.29)、负荷心肌血流量(P≥0.11)及心肌血流储备(P≥0.51)均无显著差异。

临床怎么用

  • 作者认为SiPM PET是铷-82心肌灌注显像的可靠技术。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: PET scanners using silicon photomultipliers with digital readout (SiPM PET) have an improved temporal and spatial resolution compared to PET scanners using conventional photomultiplier tubes (PMT PET). However, the effect on image quality and visibility of perfusion defects in myocardial perfusion imaging (MPI) is unknown. Our aim was to determine the value of a SiPM PET scanner in MPI. METHODS: We prospectively included 30 patients who underwent rest and regadenoson-induced stress Rubidium-82 (Rb-82) MPI on the D690 PMT PET (GE Healthcare) and within three weeks on the Vereos SiPM PET (Philips Healthcare). Two expert readers scored the image quality and assessed the existence of possible defects. In addition, interpreter's confidence, myocardial blood flow (MBF), and myocardial flow reserve (MFR) values were compared. RESULTS: Image quality improved (P = 0.03) using the Vereos as compared to the D690. Image quality of the Vereos and the D690 was graded fair in 20% and 10%, good in 60% and 50%, and excellent in 20% and 40%, respectively. Defect interpretation and interpreter's confidence did not differ between the D690 and the Vereos (P > 0.50). There were no significant differences in rest MBF (P ≥ 0.29), stress MBF (P ≥ 0.11), and MFR (P ≥ 0.51). CONCLUSION: SiPM PET provides an improved image quality in comparison with PMT PET. Defect interpretation, interpreter's confidence, and absolute blood flow measurements were comparable between both systems. SiPM PET is therefore a reliable technique for MPI using Rb-82. TRIAL REGISTRATION: ToetsingOnline NL63853.075.17. Registered 13 November, 2017.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Koenders SS, van Dalen JA, Jager PL, et al. Value of SiPM PET in myocardial perfusion imaging using Rubidium-82. J Nucl Cardiol. 2020. PMID: 32410059. doi:10.1007/s12350-020-02141-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。