文献速递心脏核医学

在SiPM PET-CT系统上对铷-82数据驱动运动校正算法的初步评估

A preliminary evaluation of a high temporal resolution data-driven motion correction algorithm for rubidium-82 on a SiPM PET-CT system.
PubMed 文献 · J Nucl Cardiol · 2020-05-21

本研究在心脏体模和36例铷-82心肌灌注显像患者中评估了一种专为心脏PET设计的数据驱动运动校正(DDMC)原型算法。体模实验显示DDMC能近乎完美恢复心肌壁可视化和缺损定量;临床图像中DDMC将非诊断图像从10例降至0例,良好图像从5例增至40例。

要点

  • DDMC在体模中近乎完美恢复心肌壁可视化和缺损定量。
  • 临床图像质量:NMC组10例非诊断、31例合格、5例良好;DDMC组0例非诊断、6例合格、40例良好。
  • DDMC在铷-82 MPI PET中显示出大幅提升图像质量并可能挽救因运动模糊而视为非诊断图像的潜力。

核心结论

  • DDMC算法在铷-82心肌灌注显像PET中显示出很大前景,图像质量大幅改善,并有可能挽救因显著运动模糊而被视为非诊断的图像。

研究设计与样本

  • 研究纳入一个带实性缺损的心脏躯干体模,分别进行静止扫描和沿轴向随机来回手动拉动扫描;并选取36例铷-82 MPI患者的46幅静态灌注图像,基于图像中运动模糊的感知进行选择;重建NMC和DDMC图像,盲法评分图像质量和感知运动。

主要发现

  • 体模数据表明,与静止体模相比,DDMC近乎完美地恢复了心肌壁可视化和缺损定量。
  • 临床图像质量评分:NMC组10例非诊断、31例合格、5例良好;DDMC组0例非诊断、6例合格、40例良好。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In myocardial perfusion PET, images are acquired during vasodilator stress, increasing the likelihood of intra-frame motion blurring of the heart in reconstructed static images to assess relative perfusion. This work evaluated a prototype data-driven motion correction (DDMC) algorithm designed specifically for cardiac PET. METHODS: A cardiac torso phantom, with a solid defect, was scanned stationary and being manually pulled to-and-fro in the axial direction with a random motion. Non-motion-corrected (NMC) and DDMC images were reconstructed. Total perfusion deficit was measured in the defect and profiles through the cardiac insert were defined. In addition, 46 static perfusion images from 36 rubidium-82 MPI patients were selected based upon a perception of motion blurring in the images. NMC and DDMC images were reconstructed, blinded, and scored on image quality and perceived motion. RESULTS: Phantom data demonstrated near-perfect recovery of myocardial wall visualization and defect quantification with DDMC compared with the stationary phantom. Quality of clinical images was NMC: 10 non-diagnostic, 31 adequate, and 5 good; DDMC images: 0 non-diagnostic, 6 adequate, and 40 good. CONCLUSION: The DDMC algorithm shows great promise in rubidium MPI PET with substantial improvements in image quality and the potential to salvage images considered non-diagnostic due to significant motion blurring.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Armstrong IS, Hayden C, Memmott MJ, et al. A preliminary evaluation of a high temporal resolution data-driven motion correction algorithm for rubidium-82 on a SiPM PET-CT system. J Nucl Cardiol. 2020. PMID: 32440990. doi:10.1007/s12350-020-02177-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。