文献速递肿瘤 PET/CT核素与放射性配体治疗

基于CT的影像组学模型用于检测PSMA放射引导手术患者的前列腺癌淋巴结转移

A CT-based radiomics model to detect prostate cancer lymph node metastases in PSMA radioguided surgery patients.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-05-28

本研究基于80例接受PSMA放射引导手术且所有可疑淋巴结均有组织学确认的前列腺癌患者,开发基于CT的影像组学模型预测淋巴结转移状态。47例(87枚淋巴结)本院影像为训练队列,33例(62枚淋巴结)外部影像为测试队列,提取156个影像组学特征。联合影像组学模型测试AUC达0.95,显著优于淋巴结短径(AUC 0.84)、淋巴结体积(AUC 0.80)和专家评分(AUC 0.67)。

要点

  • 联合影像组学模型检测淋巴结转移的测试AUC为0.95,优于常规CT参数。
  • LBP特征对模型性能贡献最高。
  • 决策曲线分析显示影像组学模型临床净获益高于淋巴结短径。

核心结论

  • 最佳影像组学模型在检测淋巴结转移方面优于常规指标,显示出影像组学特征的增量价值。

研究设计与样本

  • 回顾性分析80例因PSMA PET/CT阳性淋巴结转移接受RGS的前列腺癌患者。
  • 47例(87枚淋巴结)接受本院影像检查者作为训练队列,33例(62枚淋巴结)接受外部影像检查者作为测试队列。
  • 所有淋巴结均以组织学确认作为金标准。
  • 预处理后提取156个影像组学特征,涵盖纹理、形状、强度和局部二值模式(LBP)。
  • 采用最小绝对收缩和选择算子(影像组学模型)及逻辑回归(常规参数)建模。

主要发现

  • 纹理和形状特征与淋巴结体积高度相关。
  • 联合影像组学模型预测性能最佳,测试AUC为0.95。
  • LBP特征对模型性能贡献最高。
  • 该模型显著优于所有常规CT参数,包括淋巴结短径(AUC 0.84)、淋巴结体积(AUC 0.80)和专家评分(AUC 0.67)。
  • 淋巴结特异性决策曲线分析显示,临床净获益高于淋巴结短径。

关键数值与推荐

  • 联合影像组学模型测试AUC为0.95。
  • 淋巴结短径AUC为0.84。
  • 淋巴结体积AUC为0.80。
  • 专家评分AUC为0.67。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: In recurrent prostate carcinoma, determination of the site of recurrence is crucial to guide personalized therapy. In contrast to prostate-specific membrane antigen (PSMA)-positron emission tomography (PET) imaging, computed tomography (CT) has only limited capacity to detect lymph node metastases (LNM). We sought to develop a CT-based radiomic model to predict LNM status using a PSMA radioguided surgery (RGS) cohort with histological confirmation of all suspected lymph nodes (LNs). METHODS: Eighty patients that received RGS for resection of PSMA PET/CT-positive LNMs were analyzed. Forty-seven patients (87 LNs) that received inhouse imaging were used as training cohort. Thirty-three patients (62 LNs) that received external imaging were used as testing cohort. As gold standard, histological confirmation was available for all LNs. After preprocessing, 156 radiomic features analyzing texture, shape, intensity, and local binary patterns (LBP) were extracted. The least absolute shrinkage and selection operator (radiomic models) and logistic regression (conventional parameters) were used for modeling. RESULTS: Texture and shape features were largely correlated to LN volume. A combined radiomic model achieved the best predictive performance with a testing-AUC of 0.95. LBP features showed the highest contribution to model performance. This model significantly outperformed all conventional CT parameters including LN short diameter (AUC 0.84), LN volume (AUC 0.80), and an expert rating (AUC 0.67). In lymph node-specific decision curve analysis, there was a clinical net benefit above LN short diameter. CONCLUSION: The best radiomic model outperformed conventional measures for detection of LNM demonstrating an incremental value of radiomic features.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Peeken JC, Shouman MA, Kroenke M, et al. A CT-based radiomics model to detect prostate cancer lymph node metastases in PSMA radioguided surgery patients. Eur J Nucl Med Mol Imaging. 2020. PMID: 32468251. doi:10.1007/s00259-020-04864-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。