文献速递肿瘤 PET/CT

肿瘤患者18F-FDG全身PET/CT的图像质量、病灶可检测性与采集时间

The image quality, lesion detectability, and acquisition time of 18F-FDG total-body PET/CT in oncological patients.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2020-05-18

19例肿瘤患者接受18F-FDG全身PET/CT,采集900秒数据并重建为900至18秒六组。60秒和30秒组可获得足够可接受的主观图像质量,180秒和120秒组图像质量评分良好且无显著差异。缩短采集时间时肝脏SD升高而肿瘤SUVmax和TBR不变,病灶可检测性随采集时间缩短而下降,但直至60秒组仍可维持。

要点

  • 60秒和30秒组可获得足够且可接受的主观图像质量
  • 缩短采集时间时肝脏SD升高,肿瘤SUVmax和TBR保持不变
  • 病灶可检测性随采集时间缩短而下降,但直至60秒组仍可维持

核心结论

  • 全身PET/CT可显著缩短采集时间,同时维持病灶可检测性和图像质量。

研究设计与样本

  • 研究纳入19例肿瘤患者(女6例/男13例,年龄65.6±9.4岁),在uEXPLORER扫描仪上采用3D列表模式行全身PET/CT。
  • 18F-FDG按体重给药(4.4 MBq/kg),采集时间900秒,PET数据重建为900、180、120、60、30和18秒六组。

主要发现

  • 60秒和30秒组可获得足够且可接受的主观图像质量,180秒和120秒组图像质量评分良好且无显著差异。
  • 缩短采集时间时肝脏SD升高,而肿瘤SUVmax和TBR保持不变。
  • 病灶可检测性随采集时间缩短而下降,但直至60秒组与900秒组相比仍可维持检测性能,尽管图像质量下降。

关键数值与推荐

  • 主观PET图像质量采用5分制评分(5分优;1分差),从整体质量、噪声和病灶清晰度3个方面评价。
  • 客观图像质量通过肝脏SUVmax和标准差(SD)、肿瘤SUVmax及肿瘤与背景比值(TBR)评估。
  • 病灶可检测性以900秒组为参考,计算180至18秒各组中可识别病灶的百分比。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose was to investigate the effects of short acquisition time on the image quality and the lesion detectability of oncological 18F-FDG total-body PET/CT. METHODS: Nineteen oncological patients (6/13 women/men, age 65.6 ± 9.4 years) underwent total-body PET/CT on uEXPLORER scanner using 3D list mode. The administration of 18F-FDG was weight-based (4.4 MBq/kg). The acquisition time was 900 s, and PET data were reconstructed into 900-, 180-, 120-, 60-, 30-, and 18-s duration groups. The subjective PET image quality was scored using a 5-point scale (5, excellent; 1, poor) in 3 perspectives: overall quality, noise, and lesion conspicuity. The objective image quality was evaluated by SUVmax and standard deviation (SD) of the liver, SUVmax of the tumor, and tumor-to-background ratio (TBR). The lesion detectability was the percentage of identifiable lesions in the groups of 180 to 18 s using the group 900 s as reference. RESULTS: Our results showed that sufficient and acceptable subjective image quality could be achieved with 60- and 30-s groups, and good image quality scores were given to 180- and 120-s groups without significant difference. For shortened acquisition time, SD was increased, while SUVmax of tumor and TBR remained unchanged. The lesion detectability was decreased with shorter acquisition time, but the detection performance could be maintained until the 60-s group compared with the 900-s group, although the image quality degraded. CONCLUSION: The total-body PET/CT can significantly shorten the acquisition time with maintained lesion detectability and image quality.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Zhang YQ, Hu PC, Wu RZ, et al. The image quality, lesion detectability, and acquisition time of 18F-FDG total-body PET/CT in oncological patients. Eur J Nucl Med Mol Imaging. 2020. PMID: 32424483. doi:10.1007/s00259-020-04823-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。