初步研究:左心室激动时间是否为判断左束支夺获的有用参数——经SPECT显像评估心室机械同步性验证
这项初步研究纳入68例接受左束支起搏的心动过缓患者,测量刺激至V5、V6导联R波峰的左心室激动时间(LVAT),并用SPECT MPI评估左心室机械同步性。结果显示平均LVAT为75.4±12.7 ms,LVAT<76 ms者机械同步性优于LVAT≥76 ms者,LVAT<76 ms预测正常同步性的敏感度为88.9%、特异度为87.5%。作者认为短LVAT提示SPECT显像上机械同步性良好,LVAT<76 ms可能是判断左束支夺获的实用参数。
要点
- 68例接受左束支起搏患者中,平均LVAT为75.4±12.7 ms,47例(69.1%)记录到左束支电位。
- LVAT<76 ms患者左心室机械同步性优于LVAT≥76 ms患者。
- LVAT<76 ms预测正常同步性的敏感度88.9%、特异度87.5%。
核心结论
- 短LVAT提示SPECT显像上左心室机械同步性良好,LVAT<76 ms可能是判断左束支夺获的实用参数。
研究设计与样本
- 初步研究分析68例接受左束支起搏的心动过缓适应证患者的LVAT,并从刺激至V5和V6导联R波峰测量LVAT。
- 按LVAT数值及左束支电位是否存在分组,用SPECT MPI评估的左心室机械同步性进行比较。
主要发现
- 平均LVAT为75.4±12.7 ms,47例(69.1%)记录到左束支电位。
- LVAT<76 ms患者左心室机械同步性优于LVAT≥76 ms患者。
- LVAT<76 ms或存在左束支电位者机械同步性优于LVAT≥76 ms且无左束支电位者。
- LVAT<76 ms预测正常同步性的敏感度为88.9%、特异度为87.5%。
关键数值与推荐
- LVAT<76 ms预测正常机械同步性的敏感度为88.9%、特异度为87.5%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Left bundle branch (LBB) pacing has emerged as a novel pacing modality. Left ventricular activation time (LVAT) was reported to be associated with the activation via LBB, but the value of LVAT for determining LBB pacing was unknown. We conducted a pilot study to determine if LVAT could define LBB capture by validating left ventricular (LV) mechanical synchrony. METHODS: We analyzed LVAT in 68 bradycardia-indicated patients who received LBB pacing. LVAT was measured from the stimulus to R-wave peak in lead V5 and V6. LV mechanical synchrony assessed by SPECT MPI was compared according to the value of LVAT and the presence of LBB potential. RESULTS: The mean LVAT was 75.4 ± 12.7 ms. LBB potential was recorded in 47 patients (69.1%). Patients with LVAT < 76 ms had better LV mechanical synchrony than those with LVAT ≥ 76 ms. Patients with LVAT < 76 ms or LBB potential had better mechanical synchrony than those with LVAT ≥ 76 ms and no potential. LVAT < 76 ms could predict the normal synchrony with a sensitivity of 88.9% and a specificity of 87.5%. CONCLUSION: A short LVAT indicated favorable mechanical synchrony in SPECT imaging. LVAT < 76 ms might be a practical parameter for defining LBB capture.
引用
- Qian Z, Wang Y, Hou X, et al. A pilot study to determine if left ventricular activation time is a useful parameter for left bundle branch capture: Validated by ventricular mechanical synchrony with SPECT imaging. J Nucl Cardiol. 2020. PMID: 32333279. doi:10.1007/s12350-020-02111-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。