文献速递心脏核医学

心肌存活是否与左心室收缩不同步相关?门控SPECT-MPI同步评估

Could myocardial viability be related to left ventricular dyssynchrony? Simultaneous evaluation by gated SPECT-MPI.
PubMed 文献 · J Nucl Cardiol · 2020-04-03

本研究纳入54例缺血性扩张型心肌病伴左心室射血分数降低的患者,行两日静息/硝酸甘油门控SPECT心肌灌注显像评估心肌存活。结果显示,25例存活组在硝酸甘油后LVEF升高、收缩末期容积降低,相位标准差和相位直方图带宽均显著减小;29例非存活组功能和不同步指标无显著变化。结论认为,静息/硝酸甘油门控SPECT-MPI检测的心肌存活可能决定左心室收缩不同步的改善。

要点

  • 缺血性扩张型心肌病伴LVEF降低患者中,硝酸甘油后存活组LVEF升高且收缩末期容积降低。
  • 存活组硝酸甘油后相位标准差和相位直方图带宽均显著减小,非存活组无显著变化。
  • 静息/硝酸甘油门控SPECT-MPI检测的心肌存活可能决定左心室收缩不同步的改善。

核心结论

  • 在缺血性扩张型心肌病伴左心室射血分数降低的患者中,静息/硝酸甘油门控SPECT-MPI检测的心肌存活可能决定左心室收缩不同步的改善。

研究设计与样本

  • 连续纳入54例缺血性扩张型心肌病伴左心室射血分数降低的患者,行两日静息/硝酸甘油门控SPECT心肌灌注显像。
  • 以硝酸甘油后至少两个连续功能不全节段摄取较基线增加>10%,或摄取无改善但硝酸甘油后摄取>50%定义为存活;无硝酸甘油诱导摄取增加>10%且摄取<50%定义为非存活。
  • 比较25例存活患者与29例非存活患者在基线和硝酸甘油后的灌注、功能和左心室收缩不同步指标。

主要发现

  • 硝酸甘油后存活组LVEF升高(36.44 ± 6.64% vs 39.84 ± 6.39%),收缩末期容积降低(119.28 ± 31.77 mL vs 109.08 ± 33.17 mL)(P < 0.01)。
  • 存活组硝酸甘油后相位标准差减小(57.77° ± 19.47° vs 52.02° ± 17.09°),相位直方图带宽减小(190.20° ± 78.83° vs 178.0° ± 76.14°)(P < 0.05)。
  • 非存活组功能和左心室收缩不同步指标在硝酸甘油前后保持相似(P > 0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Left ventricular contraction dyssynchrony (LVCD) has been related to induced ischemia and transmural scar but the interplay of myocardial viability and dyssynchrony is unknown. The aim of the present study was to establish the role of dyssynchrony in the context of a viability study performed with nitrate augmentation gated single photon emission computed tomography (GSPECT) myocardial perfusion imaging (MPI). METHODS: Fifty-four consecutive patients with ischemic dilated cardiomyopathy (IDC) and depressed left ventricular ejection fraction (LVEF) were included. They underwent a two-day rest/nitroglycerine (NTG) study GSPECT MPI to determine the myocardial viability. Patients with a nitrate-induced uptake increase of > 10% vs baseline, in at least, two consecutive dysfunctional segments were considered viable as well as those who showed no improvement in the uptake but the uptake was > 50% on post NTG study. Patients with no nitrate-induced uptake increase of > 10% and the uptake of < 50% were considered non-viable. Perfusion, function and LVCD were compared in 25 viable patients vs 29 non-viable patients at baseline and after NTG administration. RESULTS: After NTG administration, in the viable group, the LVEF increased (36.44 ± 6.64% vs 39.84 ± 6.39%) and the end-systolic volume decreased significantly (119.28 ± 31.77 mL vs 109.08 ± 33.17 mL) (P < 0.01). These patients also experienced a significant reduction in the LVCD variables: phase standard deviation was reduced in the post NTG study (57.77° ± 19.47° vs 52.02° ± 17.09°) as well as the phase histogram bandwidth (190.20° ± 78.83° vs 178.0° ± 76.14°) (P < 0.05). Functional and LVCD variables remained similar in the non-viable patients (P > 0.05). CONCLUSION: In patients with IDC and depressed LVEF, the myocardial viability detected by rest/ NTG GSPECT MPI, might determine LVCD improvement.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Padrón K, Peix A, Cabrera L, et al. Could myocardial viability be related to left ventricular dyssynchrony? Simultaneous evaluation by gated SPECT-MPI. J Nucl Cardiol. 2020. PMID: 32246407. doi:10.1007/s12350-020-02047-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。