一种用于通过18F-正电子发射断层成像和荧光非侵入性监测脑脊液流动的近红外探针
研究将市售近红外染料IR-783化学修饰并氟-18标记为[18F]-IR783-AMBF3,经鞘内注射至正常及脑脊液流动异常的大鼠模型,用荧光和PET/MRI或PET/CT成像评估。结果显示该探针在含脑脊液区域清晰分布,穿透血液和皮肤成像脑脊液流动及硬膜下腰腹腔分流方面优于短波长荧光素等效物,在测试剂量下体外和体内均安全。
要点
- [18F]-IR783-AMBF3经鞘内注射后可在含脑脊液体积中清晰分布,并被PET和荧光显像。
- IR783-AMBF3在穿透血液(出血)和经皮成像硬膜下腰腹腔分流脑脊液流动方面优于短波长荧光素等效物。
- IR783-AMBF3在测试剂量下体外和体内均安全。
核心结论
- IR783-AMBF3优越的成像特性可能提高患者治疗的准确性,并协助外科医生非侵入性地诊断中枢神经系统疾病。
研究设计与样本
- 研究将市售近红外染料IR-783化学修饰并氟-18标记为[18F]-IR783-AMBF3,鞘内注射至正常及脑脊液流动异常的大鼠模型,用荧光和PET/MRI或PET/CT成像模式评估。
主要发现
- IR783-AMBF3经PET和荧光在含脑脊液体积中清晰分布。
- IR783-AMBF3(激发/发射778/793 nm)在穿透血液(出血)成像和经皮成像硬膜下腰腹腔分流脑脊液流动方面优于短波长荧光素等效物(激发/发射495/511 nm)。
- IR783-AMBF3在测试剂量下体外和体内均安全。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Knowing the precise flow of cerebrospinal fluid (CSF) is important in the management of multiple neurological diseases. Technology for non-invasively quantifying CSF flow would allow for precise localization of injury and assist in evaluating the viability of certain devices placed in the central nervous system (CNS). METHODS: We describe a near-infrared fluorescent dye for accurately monitoring CSF flow by positron emission tomography (PET) and fluorescence. IR-783, a commercially available near-infrared dye, was chemically modified and radiolabeled with fluorine-18 to give [18F]-IR783-AMBF3. [18F]-IR783-AMBF3 was intrathecally injected into the rat models with normal and aberrant CSF flow and evaluated by the fluorescence and PET/MRI or PET/CT imaging modes. RESULTS: IR783-AMBF3 was clearly distributed in CSF-containing volumes by PET and fluorescence. We compared IR783-AMBF3 (fluorescent at 778/793 nm, ex/em) to a shorter-wavelength, fluorescein equivalent (fluorescent at 495/511 nm, ex/em). IR783-AMBF3 was superior for its ability to image through blood (hemorrhage) and for imaging CSF-flow, through-skin, in subdural-run lumboperitoneal shunts. IR783-AMBF3 was safe under the tested dosage both in vitro and in vivo. CONCLUSION: The superior imaging properties of IR783-AMBF3 could lead to enhanced accuracy in the treatment of patients and would assist surgeons in non-invasively diagnosing diseases of the CNS.
引用
- Guo H, Kommidi H, Lekaye CC, et al. A near-infrared probe for non-invasively monitoring cerebrospinal fluid flow by 18F-positron emitting tomography and fluorescence. EJNMMI Res. 2020. PMID: 32301036. doi:10.1186/s13550-020-0609-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。