基于深度学习的心肌灌注SPECT衰减图生成
本研究利用65例患者的心脏SPECT/CT图像,以CT衰减图为标签,训练深度全卷积神经网络并从SPECT发射数据直接生成衰减图;合成衰减图与CT衰减图全局归一化平均绝对误差为3.60%±0.85%,重建图像高度一致,有望用于仅SPECT系统的衰减校正。
要点
- 以光峰窗和散射窗SPECT图像为输入,用深度全卷积神经网络从发射数据生成衰减图。
- 合成衰减图与CT衰减图全局归一化平均绝对误差在25例测试者中为3.60%±0.85%。
- 合成衰减图校正后的SPECT重建图像与CT衰减图校正结果高度一致。
核心结论
- 作者开发了深度卷积神经网络,可从SPECT发射数据直接估计衰减图,生成高度可靠的衰减图以促进仅SPECT扫描仪的心肌灌注成像衰减校正。
研究设计与样本
- 研究纳入65例患者的心脏SPECT/CT图像,以CT衰减图为标签进行训练和测试,实现并评估了深度全卷积神经网络,采用标准训练和对抗策略训练两种方式。
主要发现
- 合成衰减图与CT衰减图在定性定量上一致,25例测试者中全局归一化平均绝对误差为3.60%±0.85%。
- 使用合成衰减图与CT衰减图校正后的SPECT重建图像高度一致,两者间归一化平均绝对误差为0.26%±0.15%。
- 左心室心肌局部绝对百分比误差为1.33%±3.80%,左心室血池为1.07%±2.58%。
临床怎么用
- 作者认为所提方法能生成高度可靠的衰减图,以促进仅SPECT扫描仪的心肌灌注成像衰减校正。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Attenuation correction using CT transmission scanning increases the accuracy of single-photon emission computed tomography (SPECT) and enables quantitative analysis. Current existing SPECT-only systems normally do not support transmission scanning and therefore scans on these systems are susceptible to attenuation artifacts. Moreover, the use of CT scans also increases radiation dose to patients and significant artifacts can occur due to the misregistration between the SPECT and CT scans as a result of patient motion. The purpose of this study is to develop an approach to estimate attenuation maps directly from SPECT emission data using deep learning methods. METHODS: Both photopeak window and scatter window SPECT images were used as inputs to better utilize the underlying attenuation information embedded in the emission data. The CT-based attenuation maps were used as labels with which cardiac SPECT/CT images of 65 patients were included for training and testing. We implemented and evaluated deep fully convolutional neural networks using both standard training and training using an adversarial strategy. RESULTS: The synthetic attenuation maps were qualitatively and quantitatively consistent with the CT-based attenuation map. The globally normalized mean absolute error (NMAE) between the synthetic and CT-based attenuation maps were 3.60% ± 0.85% among the 25 testing subjects. The SPECT reconstructed images corrected using the CT-based attenuation map and synthetic attenuation map are highly consistent. The NMAE between the reconstructed SPECT images that were corrected using the synthetic and CT-based attenuation maps was 0.26% ± 0.15%, whereas the localized absolute percentage error was 1.33% ± 3.80% in the left ventricle (LV) myocardium and 1.07% ± 2.58% in the LV blood pool. CONCLUSION: We developed a deep convolutional neural network to estimate attenuation maps for SPECT directly from the emission data. The proposed method is capable of generating highly reliable attenuation maps to facilitate attenuation correction for SPECT-only scanners for myocardial perfusion imaging.
引用
- Shi L, Onofrey JA, Liu H, et al. Deep learning-based attenuation map generation for myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. 2020. PMID: 32219492. doi:10.1007/s00259-020-04746-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。