文献速递肿瘤 PET/CT核素与放射性配体治疗

根治性前列腺切除术中68Ga-PSMA切伦科夫发光成像评估手术切缘的可行性研究

Intraoperative 68Ga-PSMA Cerenkov Luminescence Imaging for Surgical Margins in Radical Prostatectomy: A Feasibility Study.
PubMed 文献 · J Nucl Med · 2020-02-14

单中心可行性研究纳入10例高危原发性前列腺癌患者,行68Ga-PSMA PET/CT后行根治性前列腺切除术,并对切除前列腺行术中切伦科夫发光成像(CLI),与术后组织病理学比较切缘状态。结果显示3例病理阳性手术切缘中2例被CLI准确检出,35个感兴趣区中25个(72%)可见肿瘤信号,中位肿瘤辐射亮度为11,301 photons/s/cm2/sr(范围3,328-25,428),中位肿瘤-本底比为4.2(范围2.1-11.6);假阳性信号主要位于前列腺基底部。

要点

  • 68Ga-PSMA CLI可在术中成像整个标本表面,检出切缘前列腺癌组织。
  • 10例中3例病理阳性切缘,CLI准确检出其中2例。
  • 35个感兴趣区中25个(72%)显示肿瘤信号,中位肿瘤-本底比4.2。

核心结论

  • 68Ga-PSMA CLI是一种新的术中成像技术,能够成像整个标本表面以检出切缘处前列腺癌组织。
  • 需进一步优化CLI方案或使用更低能量成像示踪剂如18F-PSMA以减少假阳性。
  • 将开展更大规模研究评估诊断性能。

研究设计与样本

  • 单中心可行性研究,纳入10例高危原发性前列腺癌患者。
  • 患者行68Ga-PSMA PET/CT后行根治性前列腺切除术,并对切除前列腺行术中CLI。
  • 前2例患者将前列腺切开后行CLI以显示原发肿瘤。
  • 将CLI肿瘤切缘状态与术后组织病理学比较,CLI强度以肿瘤-本底比表示。

主要发现

  • 切开前列腺的CLI图像成功检出肿瘤细胞,并经组织病理学证实。
  • 10例中3例有组织病理学阳性手术切缘(PSM),3例PSM中2例被CLI准确检出。
  • 35个感兴趣区中25个(72%)根据标准组织病理学证实可见肿瘤信号。
  • 这些区域的中位肿瘤辐射亮度为11,301 photons/s/cm2/sr(范围3,328-25,428 photons/s/cm2/sr),中位肿瘤-本底比为4.2(范围2.1-11.6)。
  • 假阳性信号主要见于前列腺基底部,前列腺癌细胞被良性组织覆盖;PSMA免疫组化显示良性腺体组织强PSMA染色,影响测得的活性。

局限性

  • 原文指出需进一步优化CLI方案或使用更低能量成像示踪剂如18F-PSMA以减少假阳性。
  • 原文指出将开展更大规模研究评估诊断性能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Our objective was to assess the feasibility and accuracy of Cerenkov luminescence imaging (CLI) for assessment of surgical margins intraoperatively during radical prostatectomy. Methods: A single-center feasibility study included 10 patients with high-risk primary prostate cancer (PC). 68Ga-prostate-specific membrane antigen (PSMA) PET/CT scans were performed followed by radical prostatectomy and intraoperative CLI of the excised prostate. In addition to imaging the intact prostate, in the first 2 patients the prostate gland was incised and imaged with CLI to visualize the primary tumor. We compared the tumor margin status on CLI to postoperative histopathology. Measured CLI intensities were determined as tumor-to-background ratio. Results: Tumor cells were successfully detected on the incised prostate CLI images as confirmed by histopathology. Three of 10 men had histopathologically positive surgical margins (PSMs), and 2 of 3 PSMs were accurately detected on CLI. Overall, 25 (72%) of 35 regions of interest proved to visualize a tumor signal according to standard histopathology. The median tumor radiance in these areas was 11,301 photons/s/cm2/sr (range, 3,328-25,428 photons/s/cm2/sr), and median tumor-to-background ratio was 4.2 (range, 2.1-11.6). False-positive signals were seen mainly at the prostate base, with PC cells overlaid by benign tissue. PSMA immunohistochemistry revealed strong PSMA staining of benign gland tissue, which impacts measured activities. Conclusion: This feasibility showed that 68Ga-PSMA CLI is a new intraoperative imaging technique capable of imaging the entire specimen's surface to detect PC tissue at the resection margin. Further optimization of the CLI protocol, or the use of lower-energy imaging tracers such as 18F-PSMA, is required to reduce false-positives. A larger study will be performed to assess diagnostic performance.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Darr C, Harke NN, Radtke JP, et al. Intraoperative 68Ga-PSMA Cerenkov Luminescence Imaging for Surgical Margins in Radical Prostatectomy: A Feasibility Study. J Nucl Med. 2020. PMID: 32060212. doi:10.2967/jnumed.119.240424

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。