动态全身PET显像中基于房室模型与Patlak参数映射的病灶可探测性评估
8例肺与肝病灶分期患者的临床研究扫描总时长80分钟,共检出104个病灶,其中47个位于靶血池床位。结果表明全房室建模对含病理区域可提供补充信息,部分情况下较常规静态SUV成像诊断更准确。
要点
- 全房室建模对含病理区域可提供补充信息,部分情况下较常规静态SUV成像诊断更准确。
- SUVmax与广义线性最小二乘法的Kimax及Patlak图形分析的Ki之间观察到高相关系数。
- 静态SUV图像与Patlak图未显示的肝脏恶性病灶在K1与k2图上被清晰定位。
核心结论
- 全房室建模对含病理区域有潜力提供补充信息,部分情况下较常规静态SUV成像诊断更准确,与Patlak图形分析相比具优势。
研究设计与样本
- 模拟研究生成含3个肝病灶与3个肺病灶的数据,采用3种噪声水平、每种噪声水平20次噪声实现以评估偏差与病灶检测特征。
- 临床研究纳入8例因肺与肝病灶行分期的患者,动态与静态全身成像总扫描时间为80分钟。
- 使用本机构开发的MATLAB代码生成微观与宏观参数图。
主要发现
- 共检出104个病灶,其中47个位于靶血池床位,该床位计算了所有定量参数,从而可对所有参数进行比较分析。
- 评估包括由一位核医学专家进行的视觉判读与定量分析。
- SUVmax与广义线性最小二乘法得出的Kimax以及Patlak图形分析得出的Ki之间观察到高相关系数。
- 3个经对比增强CT证实的肝脏恶性病灶及1个经活检证实、静态SUV图像与Patlak图上不可见的肝脏恶性病灶,在K1与k2图上被清晰定位。
关键数值与推荐
- 比较的PET指标包括SUV、Patlak导出的流入速率常数(Ki)与分布容积(V)以及K1、k2、k3、血容量(bv)微观参数和广义线性最小二乘法估计的Ki。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Hybrid dynamic imaging allows not only the estimation of whole-body (WB) macroparametric maps but also the estimation of microparameters in the initial bed position targeting the blood pool region containing the pathology owing to the limited axial field of view of PET scanners. In this work, we assessed the capability of multipass WB F-FDG PET parametric imaging in terms of lesion detectability through qualitative and quantitative evaluation of simulation and clinical studies. METHODS: Simulation studies were conducted by generating data incorporating 3 liver and 3 lung lesions produced by 3 noise levels and 20 noise realizations for each noise level to estimate bias and lesion detection features. The total scan time for the clinical studies of 8 patients addressed for lung and liver lesions staging, including dynamic and static WB imaging, lasted 80 minutes. An in-house-developed MATLAB code was utilized to derive the microparametric and macroparametric maps. We compared lesion detectability and different image-derived PET metrics including the SUVs, Patlak-derived influx rate constant (Ki) and distribution volume (V) and K1, k2, k3, blood volume (bv) microparameters, and Ki estimated using the generalized linear least square approach. RESULTS: In total, 104 lesions were detected, among which 47 were located in the targeted blood pool bed position where all quantitative parameters were calculated, thus enabling comparative analysis across all parameters. The evaluation encompassed visual interpretation performed by an expert nuclear medicine specialist and quantitative analysis. High correlation coefficients were observed between SUVmax and Kimax derived from the generalized linear least square approach, as well as Ki generated by Patlak graphical analysis. Moreover, 3 contrast-enhanced CT-proven malignant lesions located in the liver and a biopsy-proven malignant liver lesion not visible on static SUV images and Patlak maps were clearly pinpointed on K1 and k2 maps. CONCLUSIONS: Our results demonstrate that full compartmental modeling for the region containing the pathology has the potential of providing complementary information and, in some cases, more accurate diagnosis than conventional static SUV imaging, favorably comparing to Patlak graphical analysis.
引用
- Zaker N, Kotasidis F, Garibotto V, et al. Assessment of Lesion Detectability in Dynamic Whole-Body PET Imaging Using Compartmental and Patlak Parametric Mapping. Clin Nucl Med. 2020. PMID: 32108696. doi:10.1097/RLU.0000000000002954
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。