文献速递肿瘤 PET/CT甲状腺核医学

复发甲状腺髓样癌患者18F-DOPA PET/CT的最佳扫描时间:动态采集研究结果

Which Is the Optimal Scan Time of 18F-DOPA PET/CT in Patients With Recurrent Medullary Thyroid Carcinoma?: Results From a Dynamic Acquisition Study.
PubMed 文献 · Clin Nucl Med · 2020-01-01

该回顾性研究纳入21例疑似复发甲状腺髓样癌(MTC)患者,行45分钟动态18F-DOPA PET/CT及全身扫描。结果显示超早期相(2-5分钟)和早期相(5-10分钟)在超过70%的病例中病灶显示优于晚期相(40-45分钟),病灶SUVmax在超早期相约2倍于最后帧,提示注射后2-5分钟即可获得最佳病灶摄取图像。

要点

  • 超早期相(2-5分钟)和早期相(5-10分钟)在超过70%的病例中病灶显示优于晚期相(40-45分钟)。
  • 病灶时间-放射性曲线显示MTC病灶快速摄取示踪剂,平均最大摄取在注射后2分钟。
  • 超早期相病灶平均SUVmax约为最后帧的2倍,平均洗脱率为-44%±33%。

核心结论

  • 本研究表明MTC病灶对18F-DOPA摄取非常快速,提示在注射示踪剂后2-5分钟病灶摄取达最大值时获取早期PET/CT图像具有应用价值。

研究设计与样本

  • 回顾性研究,纳入21例疑似复发MTC患者,行45分钟动态18F-DOPA PET/CT及全身扫描;评估三个动态采集时间间期:超早期相(2-5分钟)、早期相(5-10分钟)和晚期相(40-45分钟)。

主要发现

  • 动态采集共21个病灶,15/21例患者为PET阳性,6/21例为PET阴性。
  • 超早期相和早期相在超过70%的病例中病灶显示优于晚期相,信噪比(SNR)平均降低-45%±19%(2至45分钟)。
  • 时间-放射性曲线显示病灶快速摄取示踪剂,平均最大摄取在注射后2分钟;超早期相病灶平均SUVmax约为最后帧的2倍,平均洗脱率-44%±33%。
  • 与同视野全身显像相比,动态采集额外识别1例阳性患者和2例患者中的3个额外病灶。

关键数值与推荐

  • 超早期相(2-5分钟)和早期相(5-10分钟)病灶显示优于晚期相(40-45分钟)的病例超过70%。
  • SNR平均降低-45%±19%(2至45分钟)。
  • 超早期相病灶平均SUVmax约为最后帧的2倍,平均洗脱率-44%±33%。
  • 动态采集较同视野全身显像额外识别1例阳性患者和3个额外病灶(分布于2例患者)。

临床怎么用

  • 作者认为,MTC病灶对18F-DOPA摄取非常快速,提示在注射示踪剂后2-5分钟病灶摄取达最大值时获取早期PET/CT图像具有应用价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this retrospective study was to determine, by dynamic acquisition, the optimal scan time of F-DOPA PET/CT in patients with recurrent medullary thyroid carcinoma (MTC). METHODS: Twenty-one patients with suspected recurrent MTC underwent dynamic F-DOPA PET/CT (lasting 45 minutes) followed by whole-body scan. Three different time intervals of dynamic acquisition were evaluated: ultra-early phase (2-5 minutes), early phase (5-10 minutes), and late phase (40-45 minutes). The number and SUVmax of all detected lesions among the 3 dynamic acquisition phases were compared on qualitative and semiquantitative analyses. Time-activity curves, SUVmax washout rate between ultra-early or early phase and late phase, and signal-to-noise ratio (SNR) between lesion and background activity were also calculated. RESULTS: At dynamic acquisition, 15 of 21 patients were classified as PET-positive and 6 of 21 as PET-negative, with overall 21 detected lesions. Ultra-early and early imaging provided a better lesion visualization than late phase in more than 70% of cases, as also reflected by SNR (mean SNR reduction between 2 and 45 minutes, -45% ± 19%). Time-activity curves showed a rapid tracer accumulation in MTC lesions, with an average maximum uptake at 2 minutes after injection. Mean lesion SUVmax was 2-fold higher in ultra-early frames compared with last frames (mean washout rate, -44% ± 33%). Finally, compared with whole-body imaging in the same field of view, dynamic acquisition identified 1 additional positive patient and 3 additional lesions in 2 patients. CONCLUSIONS: Our study, showing a very fast F-DOPA uptake in MTC lesions, suggests the utility to obtain early PET/CT images, already at 2 to 5 minutes after tracer injection, when maximum lesion tracer uptake is reached.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Taralli S, Lorusso M, Capotosti A, et al. Which Is the Optimal Scan Time of 18F-DOPA PET/CT in Patients With Recurrent Medullary Thyroid Carcinoma?: Results From a Dynamic Acquisition Study. Clin Nucl Med. 2020. PMID: 31977485. doi:10.1097/RLU.0000000000002925

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。