文献速递肿瘤 PET/CT放射性药物与辐射防护

定性与定量参数在[18F]-FDG PET/CT诊断主动脉移植物感染中的诊断效能

Diagnostic performance of quantitative and qualitative parameters for the diagnosis of aortic graft infection using [18F]-FDG PET/CT.
PubMed 文献 · J Nucl Cardiol · 2020-01-06

本研究在50例临床怀疑主动脉移植物感染(AGI)的患者中行[18F]-FDG PET/CT,并纳入12例无AGI怀疑的主动脉修复术后肿瘤患者作为对照,评估五点视觉分级量表(VGS)、SUVmax及不同移植物-本底比值(GBR)的诊断效能。以标准参考确诊28例感染和34例未感染移植物,SUVmax与VGS的曲线下面积分别为0.988和0.983,与GBR相比无显著差异;两者在54例患者中结论一致,该亚组灵敏度和特异度均为100%。作者认为SUVmax定量分析与VGS定性分析对AGI诊断高度有效,应在前瞻性试验中作为结局指标进行检验。

要点

  • SUVmax与VGS诊断AGI的AUC分别为0.988和0.983,与GBR相比无显著差异。
  • SUVmax与VGS在54例患者中结论一致,该亚组灵敏度和特异度均为100%。
  • 作者认为SUVmax和VGS应在前瞻性试验中作为结局指标进行检验。

核心结论

  • SUVmax定量分析与VGS定性分析对主动脉移植物感染诊断高度有效,应在前瞻性试验中作为结局指标进行检验。

研究设计与样本

  • 对50例临床怀疑主动脉移植物感染的患者行[18F]-FDG PET/CT,并纳入12例主动脉修复术后无AGI怀疑的肿瘤患者作为对照队列。
  • 采用五点视觉分级量表(VGS)、SUVmax及不同移植物-本底比值(GBR)评估移植物周围[18F]-FDG摄取模式,并通过ROC分析比较诊断效能。
  • 以标准参考确诊28例感染移植物和34例未感染移植物。

主要发现

  • SUVmax和VGS是诊断AGI的最强预测指标,曲线下面积分别为0.988和0.983,与GBR相比无显著差异。
  • SUVmax与VGS在54例患者中结论一致且准确(两者均阳性或均阴性),该亚组灵敏度和特异度均为100%。

关键数值与推荐

  • VGS采用五点视觉分级量表评估移植物周围[18F]-FDG摄取。
  • SUVmax诊断AGI的AUC为0.988,VGS的AUC为0.983。
  • SUVmax与VGS结论一致的54例患者亚组灵敏度和特异度均为100%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim of this study was the evaluation of quantitative and qualitative parameters for the diagnosis of aortic graft infection (AGI) using [18F]-FDG PET/CT. METHODS: PET/CT was performed in 50 patients with clinically suspected AGI. 12 oncological patients with aortic repair but without suspicion of AGI were included in the analysis to serve as control cohort. The [18F]-FDG uptake pattern around the graft was assessed using (a) a five-point visual grading scale (VGS), (b) SUVmax and (c) different graft-to-background ratios (GBRs). The diagnostic performance of VGS, SUVmax and GBRs was assessed and compared by ROC analysis. RESULTS: 28 infected and 34 uninfected grafts were identified by standard of reference. SUVmax and VGS were the most powerful predictors for the diagnosis of AGI according to the area under the curve (AUC 0.988 and 0.983, respectively) without a significant difference compared to GBRs. SUVmax and VGS showed congruent and accurate findings in 54 patients (i.e. either both positive or negative), yielding sensitivity and specificity (100%) in this subgroup of patients. CONCLUSION: Quantitative analysis by SUVmax and qualitative analysis by VGS are highly effective in the diagnosis of AGI and should be tested as an outcome measure in prospective trials.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Einspieler I, Mergen V, Wendorff H, et al. Diagnostic performance of quantitative and qualitative parameters for the diagnosis of aortic graft infection using [18F]-FDG PET/CT. J Nucl Cardiol. 2020. PMID: 31907856. doi:10.1007/s12350-019-02011-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。