冠状动脉18F-氟化钠摄取与心外膜脂肪组织的关系:基于计算机断层扫描的分析
本研究纳入40例心脏CT检出至少1个冠状动脉斑块并接受18F-NaF PET/CT的患者,评估冠状动脉18F-NaF摄取与心外膜脂肪组织(EAT)CT表现的关系。结果显示斑块周围EAT密度(PLED)与斑块TBRmax正相关,识别TBRmax≥1.28的最佳PLED阈值为-97 HU,且PLED≥-97 HU是多变量分析中TBRmax≥1.28的显著预测因素。
要点
- TBRmax≥1.28组患者每人最大PLED高于TBRmax较低组(-86±12 HU vs -98±11 HU,P=0.0044)。
- 基于病灶分析(n=92),PLED与TBRmax呈正相关,识别TBRmax≥1.28的最佳PLED阈值为-97 HU。
- 校正病变位置、阻塞性狭窄及CT高风险斑块后,PLED≥-97 HU仍是TBRmax≥1.28的显著预测因素。
核心结论
- PLED升高与冠状动脉18F-NaF摄取显著相关。
- CT上EAT密度与PET上冠状动脉18F-NaF摄取的逐步分析可能为冠状动脉疾病风险预测提供新策略。
研究设计与样本
- 研究纳入40例心脏CT检出至少1个冠状动脉斑块并接受18F-NaF PET/CT的患者。
- 采用CT测量EAT体积并按体表面积指数化,评估每个斑块的CT管腔狭窄和高风险特征。
- 利用非增强CT图像计算每个斑块周围平均EAT密度作为病灶周围EAT密度(PLED)。
- 采用最大组织本底比(TBRmax)量化每个斑块的局灶性18F-NaF摄取。
主要发现
- TBRmax≥1.28(既往报道的预测冠状动脉事件最佳截断值)组与TBRmax较低组之间EAT体积指数相似。
- TBRmax≥1.28组患者每人最大PLED高于TBRmax较低组(-86±12 HU vs -98±11 HU,P=0.0044)。
- 基于病灶分析(n=92)中,PLED与TBRmax呈正相关,识别TBRmax≥1.28的最佳PLED阈值为-97 HU。
- 校正病变位置、阻塞性狭窄和CT高风险斑块的多变量分析中,PLED≥-97 HU仍是TBRmax≥1.28的显著预测因素。
关键数值与推荐
- TBRmax≥1.28为既往报道的预测冠状动脉事件最佳截断值。
- 识别TBRmax≥1.28的最佳PLED阈值为-97 HU。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: 18F-Sodium fluoride (18F-NaF) positron emission tomography (PET) has the potential to detect high-risk coronary plaques. Epicardial adipose tissue (EAT) reportedly correlates with coronary atherosclerosis progression. We evaluated the relationship between coronary arterial 18F-NaF uptake and EAT findings using computed tomography (CT). METHODS: We studied 40 patients with ≥ 1 coronary plaque detected on cardiac CT who underwent 18F-NaF PET/CT. EAT volume was measured using CT and indexed to body surface area in each patient. Each plaque was evaluated for CT-based luminal stenosis and high-risk features. The mean EAT density surrounding each plaque was calculated as perilesional EAT density (PLED) using non-contrast CT images. Focal 18F-NaF uptake in each plaque was quantified using the maximum tissue-to-background ratio (TBRmax). RESULTS: EAT volume index was similar between patients with TBRmax ≥ 1.28 (previously reported optimal cutoff to predict coronary events) and those with lower TBRmax, but patients with TBRmax ≥ 1.28 showed higher maximum PLED per patient (- 86 ± 12 Hounsfield units (HU) versus - 98 ± 11 HU, P = 0.0044). In the lesion-based analysis (n = 92), PLED was positively correlated with TBRmax, and the optimal PLED cutoff to identify TBRmax ≥ 1.28 was - 97 HU. On multivariate analysis adjusted for lesion location, obstructive stenosis, and high-risk plaque on CT, PLED ≥ - 97 HU remained a significant predictor of TBRmax ≥ 1.28. CONCLUSIONS: Increased PLED was associated with significant coronary arterial 18F-NaF uptake. Step-by-step analyses of EAT density on CT and coronary arterial 18F-NaF uptake on PET may offer novel strategies for risk prediction in coronary artery disease.
引用
- Kitagawa T, Nakamoto Y, Fujii Y, et al. Relationship between coronary arterial 18F-sodium fluoride uptake and epicardial adipose tissue analyzed using computed tomography. Eur J Nucl Med Mol Imaging. 2020. PMID: 31897585. doi:10.1007/s00259-019-04675-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。