使用碲锌镉相机对转甲状腺素蛋白相关心脏淀粉样变性患者心肌99mTc标记双膦酸盐摄取进行定量
本研究比较了67例心脏转甲状腺素蛋白淀粉样变性(ATTR)患者注射99mTc标记骨示踪剂3小时后,常规全身扫描与CZT心肌SPECT(DSPECT)的半定量分析方法。结果显示平面与重投影H:B比值无统计学差异,而3D-H:B比值较平面H:B比值升高,且3D-H:B与室间隔厚度相关性最佳(r=0.45,p<0.001);异常右心室摄取与更高的心脏滞留值相关。结论认为3D半定量分析优化了CZT SPECT对心肌骨示踪剂摄取的评估。
要点
- 平面与重投影H:B比值无统计学差异(全身扫描2.05±0.64,前位重投影1.97±0.61,左前斜重投影2.06±0.64,均p=ns)。
- 3D-H:B比值较平面H:B比值升高(3D-H:B 4.06±1.77,与全身扫描、前位重投影、左前斜重投影比较均p<0.0001)。
- 3D-H:B与室间隔厚度相关性最佳(r=0.45,p<0.001),异常右心室摄取与更高的心脏滞留值相关。
核心结论
- CZT SPECT的3D半定量分析优化了心脏淀粉样变性患者99mTc标记骨示踪剂心肌摄取的评估。
研究设计与样本
- 分析了67例ATTR患者的数据,患者均在注射99mTc标记骨示踪剂3小时后接受常规全身扫描和CZT心肌SPECT(DSPECT,Spectrum Dynamics)。
- 全身扫描采用Perugini 4级视觉评分(0=无摄取,3=心脏强摄取伴轻度/无骨摄取),并计算平面心脏与背景比值(wb-H:B)。
- CZT SPECT采用三种方法定量:前位重投影平面H:B比值(ant-H:B)、左前斜重投影平面H:B比值(LAO-H:B),以及横断面 slices 上心脏VOI平均计数除以对侧肺背景VOI的3D-H:B比值。
- 室间隔厚度通过超声心动图获取。
主要发现
- 平面与重投影数据获得的H:B比值无统计学差异:wb-H:B为2.05±0.64,ant-H:B为1.97±0.61,LAO-H:B为2.06±0.64,均p=ns。
- 3D-H:B比值较平面H:B比值升高:3D-H:B为4.06±1.77,与wb-H:B、ant-H:B和LAO-H:B比较均p<0.0001。
- Bland-Altman图显示3D与平面H:B比值的差异随心肌摄取均值增加而增大。
- 3D-H:B与室间隔厚度相关性最佳(r=0.45,p<0.001)。
- 异常右心室摄取与更高的心脏滞留值相关。
关键数值与推荐
- 视觉评分采用Perugini 4级系统:0级为无摄取,3级为心脏强摄取伴轻度/无骨摄取。
- 平面H:B比值计算基于全身扫描(wb-H:B);CZT SPECT计算前位重投影(ant-H:B)、左前斜重投影(LAO-H:B)平面H:B比值及3D-H:B比值。
- 3D-H:B比值计算为横断面 slices 上包含心脏的VOI平均计数除以对侧肺背景VOI。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We aimed to compare different methods for semi-quantitative analysis of cardiac retention of bone tracers in patients with cardiac transthyretin amyloidosis (ATTR). METHODS: Data from 67 patients with ATTR who underwent both conventional whole-body scan and a CZT myocardial SPECT (DSPECT, Spectrum Dynamics) 3 h after injection of 99mTc-labeled bone tracer were analyzed. Visual scoring of cardiac retention was performed on whole-body scan according to Perugini 4-point grading system from 0 (no uptake) to 3 (strong cardiac uptake with mild/absent bone uptake). A planar heart-to-background (H:B) ratio was calculated using whole-body scan (wb-H:B). CZT SPECT was quantified using three methods: planar H:B ratio calculated from anterior reprojection (ant-H:B), left anterior oblique reprojection (LAO-H:B), and 3D-H:B ratio calculated from transaxial slices as mean counts in a VOI encompassing the heart divided by background VOI in the contralateral lung. Interventricular septal thickness was obtained using echocardiography. RESULTS: H:Bs obtained from planar and reprojected data were not statistically different (wb-H:B, 2.05 ± 0.64, ant-H:B, 1.97 ± 0.61, LAO-H:B, 2.06 ± 0.64, all p = ns). However, 3D-H:B was increased compared to planar H:Bs (3D-H:B, 4.06 ± 1.77, all p < 0.0001 vs. wb-H:B, ant-H:B, and LAO-H:B). Bland-Altman plots demonstrated that the difference between 3D and planar H:Bs increased with the mean value of myocardial uptake. 3D-H:B was best correlated to septal thickness (r = 0.45, p < 0.001). Finally, abnormal right ventricular uptake was associated with higher values of cardiac retention. CONCLUSION: 3D semi-quantitative analysis of CZT SPECT optimized the assessment of 99mTc-labeled bone tracer myocardial uptake in patients with cardiac amyloidosis.