定量肺闪烁显像与肺段计数预测肺癌患者行电视辅助胸腔镜肺叶切除术后肺功能的前瞻性头对头比较
该前瞻性研究纳入75例计划行肺叶切除术的非小细胞肺癌患者,比较非影像肺段计数法(SC)、二维平面肺灌注闪烁显像(PS)与SPECT/CT定量预测术后肺功能的准确性。60例患者实际接受电视辅助胸腔镜肺叶切除术并测定术后FEV1和DLCO。PS与SPECT/CT在右肺各叶相对摄取差异显著,但三种方法预测的术后肺功能与实际测量值间无显著差异且相关性较强。作者认为SPECT/CT定量额外耗时费力可能对患者手术选择无附加价值,或对计划行右肺叶切除术者有益,但需进一步研究。
要点
- PS与SPECT/CT在右肺上、中、下叶相对摄取差异显著,左肺上叶差异无统计学意义。
- SC、PS、SPECT/CT预测的术后FEV1和DLCO与实际术后测量值间无显著差异,相关性R=0.6-0.76。
- 作者认为SPECT/CT定量可能对手术患者选择无附加价值,对右肺叶切除者或有益但需进一步研究。
核心结论
- 尽管PS与SPECT/CT的肺叶定量参数差异显著,但两种方法导出的预测术后肺功能结果与实际术后结果间无显著差异。
- SPECT/CT定量的额外时间和精力可能对手术患者选择无附加价值。
- SPECT/CT可能对计划行右肺叶切除术的患者有益,但需进一步研究。
研究设计与样本
- 前瞻性纳入75例计划行肺叶切除术的非小细胞肺癌患者(68%男性,平均年龄68.1±8岁)。
- 所有患者完成术前FEV1和DLCO测定,以及99mTc-大颗粒白蛋白PS和SPECT/CT定量。
- 60例患者亚组接受电视辅助胸腔镜肺叶切除术并测定术后FEV1和DLCO。
- 比较PS与SPECT/CT估计的肺叶相对摄取,并由SC、PS和SPECT/CT导出预测术后FEV1和DLCO。
- 将不同方法的预测结果与接受肺叶切除术患者的真实术后测量值进行比较。
主要发现
- PS与SPECT/CT在右肺上叶、中叶、下叶的相对摄取平均差异分别为-8.2±3.8、18.0±5.0、-11.5±6.1(P<0.001)。
- 左肺上叶平均差异为-0.4±4.4(P>0.05),左肺下叶为-2.0±4.0(P<0.001)。
- SC、PS、SPECT/CT预测的术后肺功能值与实际术后FEV1和DLCO间无显著差异,且相关性较强(R=0.6-0.76,P<0.001)。
临床怎么用
- 原文结论认为SPECT/CT定量的额外时间和精力可能对手术患者选择无附加价值。
- 作者认为SPECT/CT可能对计划行右肺叶切除术的患者有益,但需进一步研究。
局限性
- 原文结论指出SPECT/CT可能对右肺叶切除患者有益,但需进一步研究(further research is warranted)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Prediction of postoperative pulmonary function in lung cancer patients before tumor resection is essential for patient selection for surgery and is conventionally done with a nonimaging segment counting method (SC) or 2-dimensional planar lung perfusion scintigraphy (PS). The purpose of this study was to compare quantitative analysis of PS to SPECT/CT and to estimate the accuracy of SC, PS, and SPECT/CT in predicting postoperative pulmonary function in patients undergoing lobectomy. Methods: Seventy-five non-small cell lung cancer patients planned for lobectomy were prospectively enrolled (68% male; average age, 68.1 ± 8 y). All patients completed tests of preoperative forced expiratory volume capacity in 1 s (FEV1) and diffusing capacity of the lungs for carbon monoxide (DLCO), as well as 99mTc-macroaggregated albumin PS and SPECT/CT quantification. A subgroup of 60 patients underwent video-assisted thoracoscopic lobectomy and measurement of postoperative FEV1 and DLCO. Relative uptake of the lung lobes estimated by PS and SPECT/CT was compared. Predicted postoperative FEV1 and DLCO were derived from SC, PS, and SPECT/CT. Prediction results were compared between the different methods and the true postoperative measurements in patients who underwent lobectomy. Results: Relative uptake measurements differed significantly between PS and SPECT/CT in right lung lobes, with a mean difference of -8.2 ± 3.8, 18.0 ± 5.0, and -11.5 ± 6.1 for right upper, middle, and lower lobes, respectively (P < 0.001). The differences between the methods in the left lung lobes were minor, with a mean difference of -0.4 ± 4.4 (P > 0.05) and -2.0 ± 4.0 (P < 0.001) for left upper and lower lobes, respectively. No significant difference and a strong correlation (R = 0.6-0.76, P < 0.001) were found between predicted postoperative lung function values according to SC, PS, SPECT/CT, and the actual postoperative FEV1 and DLCO. Conclusion: Although lobar quantification parameters differed significantly between PS and SPECT/CT, no significant differences were found between the predicted postoperative lung function results derived from these methods and the actual postoperative results. The additional time and effort of SPECT/CT quantification may not have an added value in patient selection for surgery. SPECT/CT may be advantageous in patients planned for right lobectomy, but further research is warranted.
引用
- Arnon-Sheleg E, Haberfeld O, Kremer R, et al. Head-to-Head Prospective Comparison of Quantitative Lung Scintigraphy and Segment Counting in Predicting Pulmonary Function in Lung Cancer Patients Undergoing Video-Assisted Thoracoscopic Lobectomy. J Nucl Med. 2019. PMID: 31862797. doi:10.2967/jnumed.119.234526