文献速递心脏核医学神经核医学

认知正常老年人与痴呆患者心脏123I-MIBG SPECT图像摄取均匀性研究

Uniformity of cardiac 123I-MIBG uptake on SPECT images in older adults with normal cognition and patients with dementia.
PubMed 文献 · J Nucl Cardiol · 2019-12-09

本研究纳入31例认知正常老年人、15例阿尔茨海默病(AD)和17例路易体痴呆(DLB)患者,评估心脏123I-MIBG区域摄取模式。结果发现平面摄取正常者中区域摄取变异常见,且该异质性呈非特异性,似无助于路易体痴呆的诊断。

要点

  • 认知正常老年人中,心脏123I-MIBG区域摄取减低常见于下壁(85%)、心尖(23%)、室间隔(15%)和侧壁(8%)。
  • AD和DLB患者的区域摄取模式与认知正常老年人相似。
  • 平面心脏摄取正常的病例中,区域摄取异质性常见且呈非特异性,似无助于路易体痴呆诊断。

核心结论

  • 平面心脏摄取正常的病例中,心脏123I-MIBG区域摄取显著变异常见,区域摄取异质性似呈非特异性,不太可能有助于路易体痴呆的诊断。

研究设计与样本

  • 研究纳入31例认知正常老年人、15例阿尔茨海默病(AD)患者和17例路易体痴呆(DLB)患者,其中5例有既往心肌梗死史。
  • 具有足够心脏摄取用于区域SPECT分析的参与者(对照组29/31、AD组15/15、DLB组5/17)记录了相对摄取模式。
  • 采用经过验证的在线工具QRISK2评估对照组未来心血管事件风险。

主要发现

  • 对照组中摄取减低见于下壁(85%)、心尖(23%)、室间隔(15%)和侧壁(8%)。
  • AD和DLB患者显示与对照组相似的摄取模式。
  • 61%的病例存在肺或肝干扰。
  • 心肌梗死病例显示区域摄取减低,但平面摄取正常或临界。
  • 对照组中心血管风险评分与摄取模式之间无关系。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Some studies report that assessing regional 123I-cardiac MIBG uptake can aid in the diagnosis of Lewy body disease, but others report heterogeneity in healthy controls. We aimed to evaluate regional cardiac MIBG uptake patterns in healthy older adults and patients with dementia. METHODS: 31 older adults with normal cognition, 15 Alzheimer's disease (AD), and 17 Dementia with Lewy bodies (DLB) patients were recruited. 5 individuals had previous myocardial infarction. Participants with sufficient cardiac uptake for regional SPECT analysis (29/31 controls, 15/15 AD, 5/17 DLB) had relative uptake pattern recorded. Controls were assessed for risk of future cardiovascular events using QRISK2, a validated online tool. RESULTS: In controls uptake was reduced in the inferior wall (85%), apex (23%), septum (15%), and lateral wall (8%). AD and DLB showed similar patterns to controls. Lung or liver interference was present in 61% of cases. Myocardial infarction cases showed regional reductions in uptake, but normal/borderline planar uptake. In controls, there was no relationship between cardiovascular risk score and uptake pattern. CONCLUSIONS: Significant variability of regional cardiac 123I-MIBG uptake is common in cases with normal planar cardiac uptake. Heterogeneity of regional uptake appears non-specific and unlikely to aid in the diagnosis of Lewy body disease.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Roberts G, Lloyd JJ, Jefferson E, et al. Uniformity of cardiac 123I-MIBG uptake on SPECT images in older adults with normal cognition and patients with dementia. J Nucl Cardiol. 2019. PMID: 31820410. doi:10.1007/s12350-019-01977-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。