文献速递心脏核医学

心脏磁共振定量灌注成像与[15O]H2O正电子发射断层扫描的比较

Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-12-10

CMR测量的负荷MBF和MFR与PET仅呈中度相关,但在77%和80%的血管区域中两者判断一致。

要点

  • CMR与[15O]H2O PET测得的负荷MBF和MFR仅中度相关。
  • CMR负荷MBF和MFR检测异常心肌灌注的AUC分别为0.72和0.76。
  • CMR与PET在77%的血管区域中负荷MBF判断一致,80%的血管区域中MFR判断一致。

核心结论

  • CMR测量的负荷MBF和MFR与[15O]H2O PET仅呈中度一致,但负荷MBF和MFR在CMR与[15O]H2O PET之间的血管区域一致率分别为77%和80%。

研究设计与样本

  • CMR方案包括晚期钆增强以排除瘢痕组织,以及采用双序列单团注技术的灌注成像。
  • 在静息和血管扩张剂负荷状态下测定三个主要血管区域的绝对MBF。

主要发现

  • CMR测量的区域负荷MBF和MFR与PET测值仅中度相关(负荷MBF r=0.39,P<0.001;MFR r=0.36,P<0.001)。
  • Bland-Altman分析显示负荷MBF的偏倚为0.2±1.0 mL/min/g,MFR的偏倚为-0.5±1.2。
  • CMR负荷MBF和MFR的曲线下面积分别为0.72(95%CI:0.65-0.79)和0.76(95%CI:0.69-0.83)。
  • 检测异常心肌灌注(定义为[15O]H2O PET负荷MBF≤2.3 mL/min/g且MFR≤2.5)的最佳截断值分别为2.35 mL/min/g和2.25。
  • 采用上述截断值,CMR与PET在负荷MBF上一致137个(77%)血管区域,在MFR上一致135个(80%)血管区域。

关键数值与推荐

  • 异常心肌灌注定义为[15O]H2O PET衍生的负荷MBF≤2.3 mL/min/g且MFR≤2.5。
  • CMR负荷MBF检测异常心肌灌注的最佳截断值为2.35 mL/min/g,MFR的最佳截断值为2.25。
  • CMR负荷MBF的AUC为0.72(95%CI:0.65-0.79),MFR的AUC为0.76(95%CI:0.69-0.83)。

临床怎么用

  • CMR定量负荷MBF和MFR与[15O]H2O PET仅中度一致,临床解读时应考虑模态间差异。
  • 在缺乏PET时,CMR可提供与PET约77%-80%血管区域一致的负荷MBF和MFR信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare cardiac magnetic resonance imaging (CMR) with [15O]H2O positron emission tomography (PET) for quantification of absolute myocardial blood flow (MBF) and myocardial flow reserve (MFR) in patients with coronary artery disease (CAD). METHODS: Fifty-nine patients with stable CAD underwent CMR and [15O]H2O PET. The CMR imaging protocol included late gadolinium enhancement to rule out presence of scar tissue and perfusion imaging using a dual sequence, single bolus technique. Absolute MBF was determined for the three main vascular territories at rest and during vasodilator stress. RESULTS: CMR measurements of regional stress MBF and MFR showed only moderate correlation to those obtained using PET (r = 0.39; P < 0.001 for stress MBF and r = 0.36; P < 0.001 for MFR). Bland-Altman analysis revealed a significant bias of 0.2 ± 1.0 mL/min/g for stress MBF and - 0.5 ± 1.2 for MFR. CMR-derived stress MBF and MFR demonstrated area under the curves of respectively 0.72 (95% CI: 0.65 to 0.79) and 0.76 (95% CI: 0.69 to 0.83) and had optimal cutoff values of 2.35 mL/min/g and 2.25 for detecting abnormal myocardial perfusion, defined as [15O]H2O PET-derived stress MBF ≤ 2.3 mL/min/g and MFR ≤ 2.5. Using these cutoff values, CMR and PET were concordant in 137 (77%) vascular territories for stress MBF and 135 (80%) vascular territories for MFR. CONCLUSION: CMR measurements of stress MBF and MFR showed modest agreement to those obtained with [15O]H2O PET. Nevertheless, stress MBF and MFR were concordant between CMR and [15O]H2O PET in 77% and 80% of vascular territories, respectively.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Everaars H, van Diemen PA, Bom MJ, et al. Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography. Eur J Nucl Med Mol Imaging. 2019. PMID: 31822958. doi:10.1007/s00259-019-04641-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。