本研究纳入30例连续的非缺血性心力衰竭CRT候选者,行静息18F-FDG及动态13N-NH3 PET/CT,以超声机械性失同步分为两组。失同步组室间隔FDG摄取和心肌血流量均显著低于侧壁,但仅18F-FDG室间隔/侧壁比值与机械性失同步相关,并与CRT后容积逆转重构呈负相关。

要点

  • 机械性失同步组室间隔FDG SUVmean显著低于侧壁,无失同步组分布较均匀。
  • 失同步组室间隔心肌血流量显著低于侧壁,无失同步组无差异。
  • 仅18F-FDG室间隔/侧壁比值与机械性失同步及CRT后容积逆转重构相关。

核心结论

  • 非缺血性心衰伴机械性失同步患者存在区域性代谢和心肌血流量异质性,但仅18F-FDG室间隔/侧壁比值与机械性失同步高度相关。

研究设计与样本

  • 30例连续的非缺血性CRT候选者接受静息18F-FDG和动态13N-NH3 PET/CT,依据超声是否存在机械性失同步分为有失同步组23例和无失同步组7例。

主要发现

  • 失同步组室间隔与侧壁FDG SUVmean分别为5.58±2.65和11.19±4.10,p<0.0001;无失同步组分别为7.33±2.88和8.31±2.50,p=0.30。
  • 失同步组室间隔与侧壁心肌血流量分别为0.57±0.11和0.92±0.23 ml/g/min,p<0.0001;无失同步组分别为0.61±0.23和0.77±0.21 ml/g/min,p=0.16。
  • 18F-FDG室间隔/侧壁比值与CRT后容积逆转重构呈显著负相关(r=-0.62,p=0.001)。

关键数值与推荐

  • 机械性失同步定义为超声存在室间隔闪烁和/或心尖摇摆。
  • 18F-FDG室间隔/侧壁比值与机械性失同步相关,而心肌血流量室间隔/侧壁比值未见此关联。

临床怎么用

  • 对于非缺血性心衰CRT候选者,可考虑用18F-FDG PET评估室间隔/侧壁代谢比值辅助判断机械性失同步。
  • 18F-FDG室间隔/侧壁比值低可能提示CRT后容积逆转重构较好,但样本量小需进一步验证。

局限性

  • 单中心小样本研究,无失同步组仅7例,结论需更大样本验证。
  • 机械性失同步以超声室间隔闪烁和/或心尖摇摆定义,未报告其他失同步指标。
  • 原文未报告18F-FDG室间隔/侧壁比值的具体截断值或诊断效能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: In order to better understand the concept of mechanical dyssynchrony, a promising hallmark of cardiac resynchronization therapy (CRT) response, we investigated its effect on regional myocardial metabolism and myocardial blood flow (MBF) in non-ischemic CRT candidates. RESULTS: Thirty consecutive non-ischemic CRT eligible patients underwent static 18F-FDG and resting dynamic 13N-NH3 PET/CT. 18F-FDG uptake and MBF for septal and lateral wall were analysed and septal-to-lateral wall ratios (SLR) were calculated. Based on the presence of mechanical dyssynchrony (septal flash and/or apical rocking) on echocardiography, patients were divided into 2 groups, with (n = 23) and without (n = 7) mechanical dyssynchrony. Patients with mechanical dyssynchrony had significantly lower 18F-FDG SUVmean in the septum compared with the lateral wall (5.58 ± 2.65 vs 11.19 ± 4.10, p < 0.0001), while patients without mechanical dyssynchrony had a more homogeneous 18F-FDG distribution (7.33 ± 2.88 vs 8.31 ± 2.50, respectively, p = 0.30). Similarly, MBF was significantly different between the septal and lateral wall in the dyssynchrony group (0.57 ± 0.11 ml/g/min vs 0.92 ± 0.23 ml/g/min, respectively, p < 0.0001), whereas no difference was observed in the non-dyssynchrony group (0.61 ± 0.23 ml/g/min vs 0.77 ± 0.21 ml/g/min, respectively, p = 0.16). 18F-FDG SLR, but not MBF SLR, was associated with the presence of mechanical dyssynchrony and showed a significant inverse correlation with volumetric reverse remodeling after CRT (r = - 0.62, p = 0.001). CONCLUSIONS: Non-ischemic heart failure patients with mechanical dyssynchrony demonstrate heterogeneous regional metabolism and MBF compared with patients without dyssynchrony. However, only 18F-FDG SLR appeared to be highly associated with the presence of mechanical dyssynchrony. TRIAL REGISTRATION: Clinicaltrials, NCT02537782. Registered 2 September 2015.