结合背景校正的迭代重建改善腹主动脉瘤18F-NaF PET/CT定量
本研究针对腹主动脉瘤(AAA)18F-NaF PET/CT中骨骼向瘤体的溢出污染问题,在72例患者数据集中比较OSEM、OSEM+PSF及OSEM+PSF+BC三种重建方式对AAA和AAAexc两种ROI定量结果的影响。结果显示骨骼溢出效应取决于瘤体与骨骼的邻近程度,而背景校正(OSEM+PSF+BC)使AAA定量评估不受ROI勾画方法影响,更为稳健。
要点
- AAA瘤体18F-NaF摄取显著高于正常主动脉,且与瘤体大小不相关。
- 骨骼溢出污染导致OSEM与OSEM+PSF在AAA与AAAexc ROI间定量存在显著差异。
- OSEM+PSF+BC可消除ROI勾画方法对AAA定量评估的影响。
核心结论
- 背景校正技术(OSEM+PSF+BC)无论采用何种AAA ROI勾画方法均可提供更稳健的AAA定量评估,可作为18F-NaF AAA研究的有效溢出校正方法。
研究设计与样本
- 回顾性分析72例腹主动脉瘤患者的18F-NaF PET/CT数据集,分别用OSEM、OSEM+PSF及OSEM+PSF+BC重建。
- 设置两个靶区ROI:覆盖整个动脉瘤(AAA)和排除靠近骨骼部分的动脉瘤(AAAexc)。
- 以右心房区域平均SUV为血池参考,比较SUVmax(T)、校正cSUVmax及靶本比TBR。
主要发现
- 动脉瘤18F-NaF摄取显著高于正常主动脉,且与动脉瘤大小不相关。
- 使用AAA与AAAexc两种ROI时,OSEM与OSEM+PSF的动脉瘤摄取定量存在显著差异,而OSEM+PSF+BC无此差异,归因于骨骼溢出污染。
- 骨骼溢出效应取决于动脉瘤与骨骼的邻近程度,靠近骨骼的动脉瘤溢出污染更严重。
临床怎么用
- 在18F-NaF PET/CT评估腹主动脉瘤时,建议采用结合背景校正的迭代重建(OSEM+PSF+BC)以减少骨骼溢出对定量的影响。
- 采用背景校正后,无需手动排除靠近骨骼的动脉瘤区域即可获得稳健的定量结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A confounding issue in [18F]-NaF PET/CT imaging of abdominal aortic aneurysms (AAA) is the spill in contamination from the bone into the aneurysm. This study investigates and corrects for this spill in contamination using the background correction (BC) technique without the need to manually exclude the part of the AAA region close to the bone. METHODS: Seventy-two (72) datasets of patients with AAA were reconstructed with the standard ordered subset expectation maximization (OSEM) algorithm incorporating point spread function (PSF) modelling. The spill in effect in the aneurysm was investigated using two target regions of interest (ROIs): one covering the entire aneurysm (AAA), and the other covering the aneurysm but excluding the part close to the bone (AAAexc). ROI analysis was performed by comparing the maximum SUV in the target ROI (SUVmax(T)), the corrected cSUVmax (SUVmax(T) - SUVmean(B)) and the target-to-blood ratio (TBR = SUVmax(T)/SUVmean(B)) with respect to the mean SUV in the right atrium region. RESULTS: There is a statistically significant higher [18F]-NaF uptake in the aneurysm than normal aorta and this is not correlated with the aneurysm size. There is also a significant difference in aneurysm uptake for OSEM and OSEM + PSF (but not OSEM + PSF + BC) when quantifying with AAA and AAAexc due to the spill in from the bone. This spill in effect depends on proximity of the aneurysms to the bone as close aneurysms suffer more from spill in than farther ones. CONCLUSION: The background correction (OSEM + PSF + BC) technique provided more robust AAA quantitative assessments regardless of the AAA ROI delineation method, and thus it can be considered as an effective spill in correction method for [18F]-NaF AAA studies.
引用
- Akerele MI, Karakatsanis NA, Forsythe RO, et al. Iterative reconstruction incorporating background correction improves quantification of [18F]-NaF PET/CT images of patients with abdominal aortic aneurysm. J Nucl Cardiol. 2019. PMID: 31721093. doi:10.1007/s12350-019-01940-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。