脑脊液掩模算法对123I-Ioflupane SPECT诊断帕金森综合征效能的影响
本研究纳入163例帕金森综合征(PS)患者和158例无PS患者,比较常规SBR与经脑脊液掩模算法校正的SBR(CSF-mask)对PS的诊断效能,并评估脑室扩张(以Evans指数EI评估)对算法效果的影响。ROC分析显示CSF-mask算法整体优于非校正算法,尤其在脑室扩张病例中改善更明显。
要点
- CSF-mask算法可提升SBR指数诊断PS的效能,衰减校正时AUC从0.903升至0.930。
- 无衰减校正时,低EI组两种算法AUC无显著差异(p=0.11)。
- 中、高EI组中CSF-mask算法均优于非校正算法(p<0.05或p<0.01)。
核心结论
- CSF-mask算法改善了SBR指数诊断帕金森综合征的效能,尤其在脑室扩张病例中更为明显。
研究设计与样本
- 纳入163例帕金森综合征患者和158例无帕金森综合征患者,计算常规SBR与CSF-mask校正SBR,采用ROC分析比较诊断效能。
主要发现
- 无衰减校正时,CSF-mask算法AUC为0.917(95%CI 0.887-0.947),非校正算法为0.895(95%CI 0.861-0.929),p<0.001。
- 衰减校正时,CSF-mask算法AUC为0.930(95%CI 0.902-0.957),非校正算法为0.903(95%CI 0.870-0.936),p<0.001。
- 无衰减校正时,低EI组两种算法AUC无显著差异(0.942 [95%CI 0.898-0.986] vs. 0.927 [95%CI 0.877-0.978],p=0.11)。
- 无衰减校正时,中EI组CSF-mask算法AUC为0.894(95%CI 0.825-0.963)优于非校正0.872(95%CI 0.798-0.947),p<0.05;高EI组0.931(95%CI 0.883-0.978)优于0.900(95%CI 0.840-0.961),p<0.01。
- 衰减校正时,低、中、高EI组CSF-mask算法AUC均显著优于非校正算法(p<0.05、p<0.005、p<0.005)。
关键数值与推荐
- CSF-mask算法在无衰减校正时整体AUC 0.917(95%CI 0.887-0.947),衰减校正时0.930(95%CI 0.902-0.957)。
- 无衰减校正低EI组CSF-mask算法AUC 0.942(95%CI 0.898-0.986),与非校正算法差异无统计学意义(p=0.11)。
- 衰减校正低EI组CSF-mask算法AUC 0.961(95%CI 0.924-0.998),非校正0.942(95%CI 0.895-0.988),p<0.05。
临床怎么用
- 在123I-Ioflupane SPECT诊断帕金森综合征时,采用CSF-mask算法计算SBR可提高诊断效能,对脑室扩张患者尤应使用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A cerebrospinal fluid (CSF)-mask algorithm has been developed to reduce the adverse influence of CSF-low-counts on the diagnostic utility of the specific binding ratio (SBR) index calculated with Southampton method. We assessed the effect of the CSF-mask algorithm on the diagnostic performance of the SBR index for parkinsonian syndromes (PS), including Parkinson's disease, and the influence of cerebral ventricle dilatation on the CSF-mask algorithm. METHODS: We enrolled 163 and 158 patients with and without PS, respectively. Both the conventional SBR (non-CSF-mask) and SBR corrected with the CSF-mask algorithm (CSF-mask) were calculated from 123I-Ioflupane single-photon emission computed tomography (SPECT) images of these patients. We compared the diagnostic performance of the corresponding indices and evaluated whether the effect of the CSF-mask algorithm varied according to the extent of ventricle dilatation, as assessed with the Evans index (EI). A receiver-operating characteristics (ROC) analysis was used for statistical analyses. RESULTS: ROC analyses demonstrated that the CSF-mask algorithm performed better than the non-CSF-mask (no correction, area under the curve [AUC] = 0.917 [95% confidence interval (CI) 0.887-0.947] vs. 0.895 [95% CI 0.861-0.929], p < 0.001; attenuation correction, AUC = 0.930 [95% CI 0.902-0.957] vs. 0.903 [95% CI 0.870-0.936], p < 0.001). When not corrected for attenuation, no significant difference in the AUC was observed in the low EI group between the non-CSF-mask and CSF-mask algorithms (0.927 [95% CI 0.877-0.978] vs. 0.942 [95% CI 0.898-0.986], p = 0.11); in the middle and high EI groups, the CSF-mask algorithm performed better than the non-CSF-mask algorithm (middle EI group, AUC = 0.894 [95% CI 0.825-0.963] vs. 0.872 [95% CI 0.798-0.947], p < 0.05; high EI group, AUC = 0.931 [95% CI 0.883-0.978] vs. 0.900 [95% CI 0.840-0.961], p < 0.01). When corrected for attenuation, significant differences in the AUC were observed in all three EI groups (low EI group, AUC = 0.961 [95% CI 0.924-0.998] vs. 0.942 [95% CI 0.895-0.988], p < 0.05; middle EI group, AUC = 0.905 [95% CI 0.843-0.968] vs. 0.872 [95% CI 0.800-0.944], p < 0.005; high EI group, AUC = 0.954 [95% CI 0.917-0.991] vs. 0.917 [95% CI 0.862-0.973], p < 0.005). CONCLUSION: The CSF-mask algorithm improved the performance of the SBR index in informing the diagnosis of PS, especially in cases with ventricle dilatation.