性别与灌注缺损可逆性对直立/仰卧CZT相机检测冠心病的影响
研究纳入260例接受冠状动脉造影、并以直立/仰卧镉锌碲(CZT)心脏相机成像的患者,分析性别、灌注缺损可逆性与成像体位对判读的影响。男性仰卧SSS≥3准确性较高(敏感度70.7%、特异度72.2%);女性仰卧SSS≥2敏感度90%、特异度35.9%,加用仰卧灌注缺损可逆性定量识别后特异度提高至53.3%、敏感度降至80%。仰卧图像检测冠心病准确性优于直立图像。
要点
- 男性仰卧SSS≥3对冠心病准确性较高,敏感度70.7%、特异度72.2%。
- 女性仰卧SSS≥2敏感度90%、特异度35.9%,加做仰卧可逆性定量后特异度53.3%、敏感度80%。
- 仰卧图像检测冠心病准确性优于直立图像。
核心结论
- 女性患者中,灌注缺损可逆性较单纯缺损大小与程度可提高冠心病检测特异度。
- 仰卧图像检测冠心病准确性优于直立图像。
研究设计与样本
- 连续队列中260例接受冠状动脉造影、并以直立/仰卧CZT心脏相机成像的患者。
- 采用多变量模型识别性别为CAD影像变量的显著效应修饰因素。
主要发现
- 男性仰卧SSS≥3准确性高(敏感度70.7%、特异度72.2%),对多变量模型贡献最大。
- 女性仰卧SSS≥2为缺损大小与严重度的最佳截断(敏感度90%、特异度35.9%)。
- 女性加用仰卧灌注缺损可逆性定量识别后特异度提高至53.3%、敏感度降至80%。
- 8个可准确预测冠心病的变量在仰卧成像时较直立更准确。
关键数值与推荐
- 男性:仰卧SSS≥3(敏感度70.7%、特异度72.2%)。
- 女性:仰卧SSS≥2(敏感度90%、特异度35.9%)。
- 女性加用仰卧灌注缺损可逆性定量识别(特异度53.3%、敏感度80%)。
临床怎么用
- 男性判读可参考仰卧SSS≥3作为缺损大小与严重度的高准确切点。
- 女性判读可参考仰卧SSS≥2,并加用仰卧灌注缺损可逆性定量识别以提高特异度。
- 判读CZT图像时优先参考仰卧图像以提高冠心病检测准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Limited data address the roles of gender, perfusion defect reversibility, and imaging position in interpretation of images acquired on an upright/supine cadmium-zinc-telluride (CZT) cardiac imaging system. METHODS AND RESULTS: From a consecutive cohort of patients imaged on an upright/supine CZT camera, 260 patients with coronary angiograms were studied. Multivariable models identified gender as a significant effect modifier for imaging variables of CAD. For males, a supine summed stress score (SSS) ≥ 3 provided high accuracy (sensitivity 70.7%, specificity 72.2%), and highest contribution to multivariable models. In females, supine SSS ≥ 2 provided the best cut-off for defect size and severity (sensitivity 90%, specificity 35.9%), but specificity was improved substantially to 53.3% with decrease in sensitivity to 80% by also requiring quantitative identification of perfusion defect reversibility in the supine position. Eight variables, accurate for predicting coronary disease, were more accurate with supine than upright imaging. CONCLUSIONS: Perfusion defect reversibility improved specificity in female patients for detection of coronary disease compared to perfusion defect size and extent alone. Supine images provided superior accuracy for detection of coronary disease compared to upright images.
引用
- Athar MW, Waqar F, Dwivedi AK, et al. Effects of gender and defect reversibility on detection of coronary disease with an upright and supine cadmium-zinc-telluride camera. J Nucl Cardiol. 2019. PMID: 31489586. doi:10.1007/s12350-019-01878-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。