J-ADNI多中心研究:淀粉样蛋白PET的体素统计分析与定量
该研究基于J-ADNI多中心166例受试者的11C-PiB PET,探索体素统计分析的可行性并与ROI法mcSUVR比较。以中央视觉判读为标准,Z-sum与mcSUVR分类阳性/阴性的敏感度分别为90.8%和91.8%、特异度分别为100%和98.5%。体素法可提供客观Z-score图与Z-sum值,作为视觉判读的辅助手段。
要点
- 体素法Z-sum与ROI法mcSUVR分类淀粉样蛋白PET阳性的敏感度和特异度相近。
- 体素法可客观呈现Z-score图,有助于轻度或局限Aβ沉积病例的判读。
- 多数不确定扫描被两种方法归为假阴性。
核心结论
- 体素统计分析方法可提供客观Z-score图和Z-sum值,作为淀粉样蛋白PET视觉判读的辅助手段。
研究设计与样本
- 研究分析J-ADNI多中心研究中166例接受11C-PiB PET的受试者,并从其他研究收集18例Aβ阴性图像构建正常数据库。
- PET图像采用无MRI的自适应模板法进行空间标准化,以预定义ROI测量mcSUVR,并基于正常数据库计算ROI内体素Z-score及Z-sum。
- 以中央视觉判读为参考标准,用ROC分析评估Z-sum和mcSUVR区分阳性与阴性扫描的能力,不确定扫描视为阳性。
主要发现
- Z-sum分类的敏感度和特异度分别为90.8%和100%,mcSUVR分别为91.8%和98.5%。
- 多数不确定扫描被Z-sum和mcSUVR均分类为假阴性。
- Z-score图正确勾画了与视觉判读相同的异常Aβ累积区域。
临床怎么用
- 体素统计分析的Z-score图和Z-sum值可作为视觉判读的辅助,尤其适用于轻度或局限Aβ累积病例。
- 该方法有望提高Aβ检测敏感度、减少判读者间变异,并支持对Aβ沉积的详细监测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Amyloid PET plays a vital role in detecting the accumulation of in vivo amyloid-β (Aβ). The quantification of Aβ accumulation has been widely performed using the region of interest (ROI)-based mean cortical standardized uptake value ratio (mcSUVR). However, voxel-based statistical analysis has not been well studied. The purpose of this study was to examine the feasibility of analyzing amyloid PET scans by voxel-based statistical analysis. The results were then compared to those with the ROI-based mcSUVR. In total, 166 subjects who underwent 11C-PiB PET in the J-ADNI multi-center study were analyzed. Additionally, 18 Aβ-negative images were collected from other studies to form a normal database. The PET images were spatially normalized to the standard space using an adaptive template method without MRI. The mcSUVR was measured using a pre-defined ROI. Voxel-wise Z-scores within the ROI were calculated using the normal database, after which Z-score maps were generated. A receiver operating characteristic (ROC) analysis was performed to evaluate whether Z-sum (sum of the Z-score) and mcSUVR could be used to classify the scans into positive and negative using the central visual read as the reference standard. PET scans that were equivocal were regarded as positive. RESULTS: Sensitivity and specificity were respectively 90.8% and 100% by Z-sum and 91.8% and 98.5% by mcSUVR. Most of the equivocal scans were subsequently classified by both Z-sum and mcSUVR as false negatives. Z-score maps correctly delineated abnormal Aβ accumulation over the same regions as the visual read. CONCLUSIONS: We examined the usefulness of voxel-based statistical analysis for amyloid PET. This method provides objective Z-score maps and Z-sum values, which were observed to be helpful as an adjunct to visual interpretation especially for cases with mild or limited Aβ accumulation. This approach could improve the Aβ detection sensitivity, reduce inter-reader variability, and allow for detailed monitoring of Aβ deposition. TRIAL REGISTRATION: The number of the J-ADNI study is UMIN000001374.
引用
- Akamatsu G, Ikari Y, Ohnishi A, et al. Voxel-based statistical analysis and quantification of amyloid PET in the Japanese Alzheimer's disease neuroimaging initiative (J-ADNI) multi-center study. EJNMMI Res. 2019. PMID: 31535240. doi:10.1186/s13550-019-0561-2