文献速递肿瘤 PET/CT甲状腺核医学

肾上腺腺瘤18F-FDG摄取与平扫CT值及组成细胞相关

Uptake of 18F-FDG in Adrenal Adenomas Is Associated With Unenhanced CT Value and Constituent Cells.
PubMed 文献 · Clin Nucl Med · 2019-01-01

本研究回顾性分析57例肾上腺腺瘤,发现18F-FDG PET的SUVmax与平扫CT衰减值呈显著正相关(R=0.44,P=0.0007)。在11例手术切除结节中,GLUT评分与CT衰减值显著正相关(R=0.68,P=0.02),与透明细胞比例(CCR)显著负相关(R=0.60,P=0.003)。结论提示肾上腺腺瘤FDG摄取可能取决于其组成细胞。

要点

  • 肾上腺腺瘤SUVmax与平扫CT衰减值呈显著正相关。
  • GLUT评分与CT衰减值正相关,与透明细胞比例负相关。
  • FDG摄取可能取决于腺瘤组成细胞(致密细胞为主者摄取高)。

核心结论

  • 由较多致密细胞组成或平扫CT高衰减的肾上腺腺瘤显示高FDG摄取,FDG摄取可能取决于组成细胞。

研究设计与样本

  • 回顾性研究57例肾上腺腺瘤,分析18F-FDG PET的SUVmax与平扫CT衰减值的相关性。
  • 对11例手术切除结节病理评估透明细胞比例(CCR)及葡萄糖转运蛋白1至4表达水平,以0至3分评分并求和为GLUT评分。

主要发现

  • 57例腺瘤中SUVmax与CT衰减值呈显著正相关(R=0.44,P=0.0007)。
  • 11例手术切除病例中SUVmax与CCR呈非显著负相关趋势(R=0.57,P=0.06)。
  • GLUT评分与CT衰减值呈显著正相关(R=0.68,P=0.02)。
  • GLUT评分与CCR呈显著负相关(R=0.60,P=0.003)。

临床怎么用

  • 解读肾上腺腺瘤FDG摄取增高时,可结合平扫CT衰减值和细胞组成(致密细胞/透明细胞比例)综合判断。

局限性

  • 病理评估仅限11例手术切除结节,样本量小。
  • SUVmax与CCR的相关性未达统计学显著性(P=0.06)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purposes of this study were to investigate the correlation between unenhanced CT attenuation values and F-FDG uptake in adrenal adenomas, and to clarify the mechanism of FDG uptake in adrenal adenomas based on immunohistochemical findings. MATERIALS AND METHODS: In 57 adrenal adenomas, the correlation between SUVmax on F-FDG PET and unenhanced CT attenuation was retrospectively investigated. In the 11 surgically resected nodules, the clear cell ratio (CCR) and expression levels of glucose transporters (GLUTs) 1 to 4 were pathologically evaluated. The GLUT expression levels were scored at 0 to 3 points for each transporter, and the sum of these expression levels was defined as the GLUT score. The relationships between CCR and either the CT attenuation number or SUVmax, and between the GLUT score and each of the CT attenutation value, SUVmax, or CCR were evaluated. RESULTS: There was a significant positive correlation between SUVmax and the CT attenuation value for the group of 57 adenomas (R = 0.44, P = 0.0007). For the 11 surgically resected cases, there was a nonsignificant trend of negative correlation between SUVmax and CCR (R = 0.57, P = 0.06). There was a significant positive correlation between GLUT score and CT attenuation value (R = 0.68, P = 0.02), and a significant negative correlation between GLUT score and CCR (R = 0.60, P = 0.003). CONCLUSIONS: Adrenal adenomas composed of many compact cells or having high attenuation on unenhanced CT showed high FDG uptake. FDG uptake of adrenal adenomas may depend on the constituent cells.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Murayama R, Nishie A, Hida T, et al. Uptake of 18F-FDG in Adrenal Adenomas Is Associated With Unenhanced CT Value and Constituent Cells. Clin Nucl Med. 2019. PMID: 31490313. doi:10.1097/RLU.0000000000002759

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。