动态铷-82心脏PET运动校正:衰减图逐帧调整对心肌血流量计算的影响
本研究在30例铷-82动态PET研究中,由三名用户逐帧进行运动校正,比较未校正、仅运动校正及运动校正联合衰减图调整三种方式对心肌血流量(MBF)的影响。结果显示,重度运动组中仅运动校正与未校正的MBF中位差异在右冠状动脉(RCA)为23%、左前降支(LAD)为18%,而联合衰减图调整后差异通常小于10%。结论认为运动校正对动态铷数据是必要的,但衰减图调整仅带来边缘差异,并非 essential 要求。
要点
- 重度运动时仅运动校正与未校正的MBF差异在RCA达23%、LAD达18%。
- 运动校正联合衰减图调整与仅运动校正的MBF差异通常小于10%。
- 溢出图均匀性可作为验证运动校正技术的视觉辅助工具。
核心结论
- 动态铷-82 PET数据运动校正是未来MBF软件更新所期望的。
- 衰减图调整仅带来边缘差异,因此不太可能是 essential 要求。
- 评估溢出图的均匀性是验证运动校正技术的有用视觉辅助。
研究设计与样本
- 在30例铷-82动态PET研究上由三名用户逐帧进行运动校正。
- 数据按运动严重程度等分为轻度(M1)、中度(M2)和重度(M3)三组。
- 比较未运动校正(NC)、仅运动校正(MC)和联合衰减图调整(MCAC)的MBF数据。
主要发现
- M3组中MC与NC图像的MBF中位差异在RCA为23%、在LAD为18%。
- MCAC与MC图像的MBF差异显著更小,通常小于10%。
- MC和MCAC的溢出图与NC图像相比明显更均匀。
临床怎么用
- 对动态铷-82 PET数据应考虑实施运动校正以改善MBF估计。
- 衰减图逐帧调整对MBF影响有限,可不作为常规必需步骤。
- 可利用溢出图均匀性作为运动校正效果的视觉验证工具。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patient motion during pharmacological stressing can have substantial impact on myocardial blood flow (MBF) estimated from dynamic PET. This work evaluated a motion correction algorithm with and without adjustment of the PET attenuation map. METHODS: Frame-by-frame motion correction was performed by three users on 30 rubidium-82 studies. Data were divided equally into three groups of motion severity [mild (M1), moderate (M2) and severe (M3)]. MBF data were compared for non-motion corrected (NC), motion-corrected-only (MC) and with adjustment of the attenuation map (MCAC). Percentage differences of MBF were calculated in the coronary territories and 17-segment polar plots. Polar plots of spill-over were also generated from the data. RESULTS: Median differences of 23% were seen in the RCA and 18% for the LAD in the M3 category for MC vs NC images. Differences for MCAC vs MC images were considerably smaller and typically < 10%. Spill-over plots for MC and MCAC were notably more uniform compared with NC images. CONCLUSION: Motion correction for dynamic rubidium data is desirable for future MBF software updates. Adjustment of the PET attenuation map results in only marginal differences and therefore is unlikely to be an essential requirement. Assessing the uniformity of spill-over plots is a useful visual aid for verifying motion correction techniques.
引用
- Armstrong IS, Memmott MJ, Saint KJ, et al. Assessment of motion correction in dynamic rubidium-82 cardiac PET with and without frame-by-frame adjustment of attenuation maps for calculation of myocardial blood flow. J Nucl Cardiol. 2019. PMID: 31388967. doi:10.1007/s12350-019-01834-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。