文献速递心脏核医学放射性药物与辐射防护

降低复杂先天性心脏病患者心肌灌注显像的辐射剂量

Reducing radiation dose from myocardial perfusion imaging in subjects with complex congenital heart disease.
PubMed 文献 · J Nucl Cardiol · 2019-08-12

该研究纳入75例复杂先天性心脏病(CHD)患者,评估不同心肌灌注显像(MPI)策略的缺陷患病率和有效辐射剂量。结果显示静息/负荷MPI异常率为43%,估计平均有效辐射剂量从13N-氨PET/CT的2.1±0.6 mSv到SPECT/CT的12.5±0.9 mSv不等。作者结论认为,采用负荷优先MPI、2天协议及先进成像技术(CZT SPECT、新重建软件、PET MPI)可大幅降低复杂CHD患者的辐射剂量。

要点

  • 复杂CHD患者静息/负荷MPI异常率为43%,其中25%异常扫描显示可逆性缺陷。
  • 估计平均有效辐射剂量范围2.1±0.6 mSv(13N-氨PET/CT)至12.5±0.9 mSv(SPECT/CT)。
  • 负荷优先MPI和2天负荷/静息协议预测有效辐射剂量显著更低。

核心结论

  • 复杂CHD患者应力MPI异常患病率相对较高,采用负荷优先MPI、2天协议及先进成像技术可大幅降低辐射剂量。

研究设计与样本

  • 研究纳入75例复杂CHD患者(年龄5至80岁),2002至2015年间转诊行MPI。
  • 使用99mTc-甲氧基异丁基异腈、82Rb或13N-氨,以及碘化钠SPECT、SPECT/CT、CZT SPECT或PET/CT扫描仪行静息和运动或药物负荷MPI。
  • 去标识图像分三批半定量判读:仅负荷MPI、负荷/静息MPI、考虑室间隔缺损修补史的负荷/静息MPI。
  • 估计负荷/静息MPI的有效辐射剂量,并预测1天负荷优先(负荷扫描正常)和2天负荷/静息MPI(负荷扫描异常)的剂量。

主要发现

  • 中位年龄18.6岁,最常见CHD类型为大动脉转位(63%)。
  • 静息/负荷MPI异常者占43%,其中25%的异常扫描显示可逆性缺陷。
  • MPI异常者中33%存在显著潜在解剖性冠状动脉阻塞。
  • 估计平均有效辐射剂量从13N-氨PET/CT的2.1±0.6 mSv到SPECT/CT的12.5±0.9 mSv。
  • 负荷优先MPI和2天负荷/静息协议的预测有效辐射剂量显著更低。

临床怎么用

  • 对复杂CHD患者行MPI时,可优先考虑负荷优先MPI方案以降低辐射剂量。
  • 可采用2天负荷/静息协议替代单日协议以降低辐射剂量。
  • 可选用CZT SPECT、新图像重建软件或PET MPI等先进技术进一步降低辐射剂量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The prevalence of defects and effective radiation dose from various myocardial perfusion imaging (MPI) strategies in congenital heart disease (CHD) is unknown. METHODS: We studied 75 subjects with complex CHD (ages 5 to 80 years) referred for MPI between 2002 and 2015. A rest and exercise or pharmacologic stress MPI was performed using 99mTechnetium sestamibi, 82rubidium or 13N-ammonia, and Sodium iodide SPECT (single-photon emission computed tomography), SPECT/CT or Cadmium zinc telluride (CZT) SPECT or PET (positron emission tomography)/CT scanners. Deidentified images were interpreted semi-quantitatively in three batches: stress only MPI, stress/rest MPI, and stress/rest MPI with taking into account a history of ventricular septal defect repair. Effective radiation dose was estimated for stress/rest MPI and predicted for 1-day stress-first (normal stress scans), and for 2-day stress/rest MPI (abnormal stress scans). RESULTS: The median age was 18.6 years. The most common type of CHD was transposition of the great arteries (63%). Rest/stress MPI was abnormal in 43% of subjects and 25% of the abnormal scans demonstrated reversible defects. Of the subjects with abnormal MPI, 33% had significant underlying anatomic coronary artery obstruction. Estimated mean effective radiation dose ranged from 2.1 ± 0.6 mSv for 13N-ammonia PET/CT to 12.5 ± 0.9 mSv for SPECT/CT. Predicted effective radiation dose was significantly lower for stress-first MPI and for 2-day stress/rest protocols. CONCLUSIONS: Due to the relatively high prevalence of abnormal stress MPI, tailored protocols with a stress-first MPI as well as the use of 2-day protocols and advanced imaging technologies including CZT SPECT, novel image reconstruction software, and PET MPI could substantially reduce radiation dose in complex CHD.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Partington SL, Valente AM, Bruyere J, et al. Reducing radiation dose from myocardial perfusion imaging in subjects with complex congenital heart disease. J Nucl Cardiol. 2019. PMID: 31407235. doi:10.1007/s12350-019-01811-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。