文献速递心脏核医学

冬眠与顿抑心肌静息血流无差异:缺血性心肌病病理生理新见解

No differences in rest myocardial blood flow in stunned and hibernating myocardium: insights into the pathophysiology of ischemic cardiomyopathy.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-07-29

研究纳入110例缺血性心肌病患者,用13N-NH3和18F-FDG PET定量灌注与存活心肌,结合超声室壁运动区分正常、顿抑、冬眠及瘢痕心肌。结果显示顿抑与冬眠心肌静息MBF和MFR均无差异,但均低于正常心肌;瘢痕心肌静息MBF最低且示踪剂洗脱率增高。

要点

  • 顿抑与冬眠心肌静息MBF和MFR无显著差异(p=0.40)。
  • 功能异常但存活心肌的静息MBF和MFR均低于正常心肌。
  • 瘢痕心肌静息MBF最低,且示踪剂洗脱率k2增高。

核心结论

  • 缺血性心肌病患者中,MFR受损与顿抑和冬眠心肌相关。
  • 顿抑与冬眠心肌的静息MBF均低于正常心肌,但两者间无差异。
  • 瘢痕心肌静息MBF最低,并伴有示踪剂洗脱率增高。

研究设计与样本

  • 纳入110例缺血性心肌病患者。
  • 采用13N-NH3和18F-FDG PET进行定量心肌灌注评估和存活心肌显像。
  • 结合超声心动图室壁运动评估,将心肌组织分为正常、顿抑、冬眠和瘢痕心肌。

主要发现

  • 与正常心肌相比,功能异常但存活心肌(包括顿抑和冬眠)静息MBF降低(0.89 mL/min/g vs. 0.79和0.76 mL/min/g;p<0.001)。
  • 与正常心肌相比,功能异常但存活心肌MFR降低(1.53 vs. 1.27和1.17;p<0.001)。
  • 顿抑与冬眠心肌之间静息MBF和MFR无差异(p=0.40)。
  • 瘢痕心肌静息MBF最低(0.66 mL/min/g;p<0.001),且k2增高(0.199/min vs. 0.178/min至0.181/min;两两比较均p<0.05)。

临床怎么用

  • 在缺血性心肌病患者中,静息MBF降低和MFR受损提示存在顿抑或冬眠心肌。
  • 瘢痕心肌表现为静息MBF最低且示踪剂洗脱率k2增高,有助于鉴别。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The human pathophysiology of stunned, hibernating and scarred myocardium in ischemic cardiomyopathy is a subject of controversy. While the "smart heart" theory postulates that reduced myocardial blood flow (MBF) at rest is responsible for myocytes switching to a state of hibernation, other theories suggest that a reduced myocardial flow reserve (MFR) may be the cause. METHODS: We included 110 patients with ischemic cardiomyopathy. Based on quantitative myocardial perfusion assessment and viability imaging with 13N-NH3 and 18F-FDG positron emission tomography, respectively, as well as wall motion assessment from echocardiography, myocardial tissue was characterized as remote (i.e., normal myocardium), stunned (i.e., dysfunctional but viable myocardium with normal rest perfusion), hibernating (i.e., dysfunctional but viable myocardium with impaired rest perfusion), or scarred myocardium (i.e., non-viable myocardium). RESULTS: Compared to remote myocardium, dysfunctional but viable myocardium (including stunned and hibernating) had reduced rest MBF (0.89 mL/min/g vs. 0.79 and 0.76 mL/min/g, respectively; p < 0.001) and MFR (1.53 vs. 1.27 and 1.17; p < 0.001). Between stunned and hibernating myocardium, however, rest MBF and MFR did not differ (p = 0.40). In scarred myocardium, rest MBF was lowest (0.66 mL/min/g; p < 0.001) but, in contrast to the other myocardial states, k2 (i.e., tracer washout) was increased (0.199/min vs. 0.178/min to 0.181/min; all p < 0.05 in pairwise comparison). CONCLUSIONS: In patients with ischemic cardiomyopathy, impaired MFR is associated with stunning and hibernation. These states of dysfunctional but viable myocardium have lower rest MBF compared to remote myocardium. At the end of the continuum, rest MBF is lowest in scar tissue and linked to increased rate of tracer washout.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Benz DC, von Dahlen AP, Huang W, et al. No differences in rest myocardial blood flow in stunned and hibernating myocardium: insights into the pathophysiology of ischemic cardiomyopathy. Eur J Nucl Med Mol Imaging. 2019. PMID: 31359109. doi:10.1007/s00259-019-04440-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。