文献速递心脏核医学

半导体SPECT心肌灌注显像前瞻性诊断性能:室壁增厚分析减少额外俯卧位采集需求

Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-07-18

该前瞻性研究纳入41例已知或疑似冠心病患者(123支血管),比较仰卧位非门控、俯卧+仰卧位非门控及仰卧位非门控+室壁增厚分析对SPECT心肌灌注显像诊断性能的影响。结果显示仰卧位非门控假阳性率显著较高,加用室壁增厚分析后特异度达96.8%,与俯卧+仰卧位采集相当,且灵敏度无显著差异。

要点

  • 仰卧位非门控SPECT MPI假阳性率20.8%,显著高于俯卧+仰卧位(3.3%)和仰卧+室壁增厚(2.7%)。
  • 仰卧+室壁增厚特异度96.8%,与俯卧+仰卧位96.1%相当,均高于仰卧位非门控76.1%。
  • 各组灵敏度无显著差异(80.0%、86.6%、73.3%),室壁增厚分析可替代俯卧位采集。

核心结论

  • 仰卧位负荷SPECT MPI加用缺血节段室壁增厚评估作为附加诊断标准,可提高诊断性能至与俯卧+仰卧位采集无显著差异的水平。

研究设计与样本

  • 前瞻性研究纳入41例已知或疑似冠心病患者(123支血管),系统进行俯卧位和仰卧位201Tl负荷SPECT MPI。
  • 以有创冠状动脉造影和血流储备分数为金标准,比较仰卧位非门控、俯卧+仰卧位非门控及仰卧位非门控+室壁增厚分析的诊断性能。

主要发现

  • 仰卧位非门控假阳性率20.8%,显著高于俯卧+仰卧位(3.3%)和仰卧+室壁增厚(2.7%),P<0.05 vs 仰卧位非门控。
  • 俯卧+仰卧位特异度96.1%高于仰卧位非门控76.1%(P<0.01);仰卧+室壁增厚特异度最高达96.8%(vs 俯卧+仰卧位P无显著差异)。
  • 各组灵敏度分别为80.0%、86.6%和73.3%,所有比较P均无显著差异。

关键数值与推荐

  • 仰卧位非门控假阳性率20.8%,俯卧+仰卧位3.3%,仰卧+室壁增厚2.7%。
  • 特异度:仰卧位非门控76.1%,俯卧+仰卧位96.1%,仰卧+室壁增厚96.8%。
  • 灵敏度:仰卧位非门控80.0%,俯卧+仰卧位86.6%,仰卧+室壁增厚73.3%。

临床怎么用

  • 在仰卧位负荷SPECT MPI中,可加用室壁增厚分析作为附加诊断标准,以减少对俯卧位采集的需求。
  • 室壁增厚分析有助于降低假阳性率,提高特异度至与俯卧+仰卧位采集相当的水平。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To determine whether the assessment of regional wall thickening (WT) in addition to myocardial perfusion from stress supine acquisitions could compensate for the lack of prone acquisition and the corresponding decrease in the diagnostic performance of SPECT myocardial perfusion imaging (MPI) in patients with known or suspected coronary artery disease (CAD). METHODS: The study group comprised 41 patients (123 vessels) with known or suspected CAD prospectively recruited for systematic prone and supine 201Tl stress SPECT MPI. The diagnostic performance of SPECT MPI was determined for various image sets including nongated supine images (supine NG), nongated combined prone and supine images (prone and supine NG) and gated supine images, allowing WT evaluation from NG images in addition to perfusion (supine NG + WT) using invasive coronary angiography and fractional flow reserve as the gold standards. RESULTS: The rate of false positives was significantly higher among the supine NG images (20.8%) than among either the prone and supine NG or the supine NG + WT images (3.3% and 2.7%, respectively, P < 0.05 vs. supine NG). Consequently, specificity was higher for the prone and supine NG images than for the supine NG images (96.1% vs. 76.1%, P < 0.01) and was highest for the supine NG + WT images (96.8%, P not significant vs. prone and supine NG), without significant differences in sensitivity (80.0%, 86.6% and 73.3%, respectively, P not significant for all comparisons). CONCLUSION: The diagnostic performance of supine stress SPECT MPI is improved when WT assessment of ischaemic segments is used as an additional diagnostic criterion to values not significantly different from those with combined prone and supine acquisitions.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Djaileb L, Dubois B, de Leiris N, et al. Prospective diagnostic performance of semiconductor SPECT myocardial perfusion imaging: wall thickening analysis reduces the need for an additional prone acquisition. Eur J Nucl Med Mol Imaging. 2019. PMID: 31321484. doi:10.1007/s00259-019-04415-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。