基于对照的去噪方法提升FDG-PET预测阿尔茨海默病转化的能力

Controls-based denoising, a new approach for medical image analysis, improves prediction of conversion to Alzheimer's disease with FDG-PET.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-07-24

本研究基于ADNI数据库220例轻度认知障碍患者和262例健康对照的FDG-PET数据,提出基于对照的去噪方法(CODE),在计算模式表达评分(PES)前去除健康对照中识别的非病理变异模式。结果显示CODE将AD-PES信噪比提升1.5倍,AUC从0.80提高至0.88,结合临床特征后AUC达0.93。

要点

  • CODE去噪使PES预测AD转化的AUC从0.80提升至0.88(p=0.001)。
  • 去噪后PES联合临床特征分类性能最佳,AUC达0.93。
  • CODE性能优于在患者数据上训练的标准支持向量机方法。

核心结论

  • CODE去噪可显著改善基于PES的AD转化预测,分类性能优于标准机器学习算法。

研究设计与样本

  • 多中心FDG-PET研究,纳入ADNI数据库220例MCI患者(64例非转化者随访≥4年,156例AD转化者转化时间≤4年)和262例健康对照。

主要发现

  • CODE使AD-PES信噪比提升1.5倍。
  • PES预测AD转化的AUC从0.80提高至0.88(p=0.001,DeLong法),敏感性从69%提高至83%,特异性从81%提高至88%,MCC从0.45提高至0.66。
  • 去噪PES联合临床特征获得最佳分类性能(AUC 0.93)。

临床怎么用

  • 在FDG-PET分析中可先利用健康对照样本通过主成分分析识别非病理变异模式并在患者数据中去除,再计算PES以提升AD转化预测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The pattern expression score (PES), i.e., the degree to which a pathology-related pattern is present, is frequently used in FDG-brain-PET analysis and has been shown to be a powerful predictor of conversion to Alzheimer's disease (AD) in mild cognitive impairment (MCI). Since, inevitably, the PES is affected by non-pathological variability, our aim was to improve classification with the simple, yet novel approach to identify patterns of non-pathological variance in a separate control sample using principal component analysis and removing them from patient data (controls-based denoising, CODE) before calculating the PES. METHODS: Multi-center FDG-PET from 220 MCI patients (64 non-converter, follow-up ≥ 4 years; 156 AD converter, time-to-conversion ≤ 4 years) were obtained from the ADNI database. Patterns of non-pathological variance were determined from 262 healthy controls. An AD pattern was calculated from AD patients and controls. We predicted AD conversion based on PES only and on PES combined with neuropsychological features and ApoE4 genotype. We compared classification performance achieved with and without CODE and with a standard machine learning approach (support vector machine). RESULTS: Our model predicts that CODE improves the signal-to-noise ratio of AD-PES by a factor of 1.5. PES-based prediction of AD conversion improved from AUC 0.80 to 0.88 (p= 0.001, DeLong's method), sensitivity 69 to 83%, specificity 81% to 88% and Matthews correlation coefficient (MCC) 0.45 to 0.66. Best classification (0.93 AUC) was obtained when combining the denoised PES with clinical features. CONCLUSIONS: CODE, applied in its basic form, significantly improved prediction of conversion based on PES. The achieved classification performance was higher than with a standard machine learning algorithm, which was trained on patients, explainable by the fact that CODE used additional information (large sample of healthy controls). We conclude that the proposed, novel method is a powerful tool for improving medical image analysis that offers a wide spectrum of biomedical applications, even beyond image analysis.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Blum D, Liepelt-Scarfone I, Berg D, et al. Controls-based denoising, a new approach for medical image analysis, improves prediction of conversion to Alzheimer's disease with FDG-PET. Eur J Nucl Med Mol Imaging. 2019. PMID: 31338550. doi:10.1007/s00259-019-04400-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。